OPTIONAL VARIABLE SPEED BLOWER INSTALLATION INSTRUCTIONS (continued)
Wiring
The appliance, when installed, must be electrically grounded in
accordance with local codes or, in the absence of local codes,
with the National Electrical Code, ANSI/NFPA 70, if an external
electrical source is utilized. This appliance is equipped with a
three-prong [grounding] plug for your protection against shock
hazard and should be plugged directly into a properly grounded
three-prong receptacle. Do not cut or remove the grounding
prong from this plug. For an ungrounded receptacle, an adapter,
which has two prongs and a wire for grounding, can be purchased,
plugged into the ungrounded receptacle and its wire connected
to the receptacle mounting screw. With this wire completing the
ground, the appliance cord plug can be plugged into the adapter
and be electrically grounded.
CAUTION: Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing.
29898-7-0714
Blower Motor
The blower motor does not have oiling holes. Do not attempt to oil
the blower motor.
Blower Wheels
The blower wheels will collect lint and could require periodic cleaning.
If the air output decreases or the noise level increases, it indicates
a dirty blower wheel. Remove blower and clean blower wheels.
WARNING:
Unplugging of blower accessory will not stop the heater
from cycling. To turn off gas to the unvented heater: Push
in gas control knob slightly and turn clockwise to "OFF."
Do not force.
FAN
SWITCH
WHITE
SPEED CONTROL
5
1
FBB4
2
R7649
3
R4192
4
R4186
110 VOLT AC
JUNCTION BOX
FAN
GROUND
BLACK
WHITE
BLACK
Figure 26
2
5
4
1
B L O W E R A S S E M B LY
COMPLETE
FAN CONTROL
SPEED CONTROL KNOB
SPEED CONTROL
Figure 27
3
Page 31