Empire Comfort Systems pmn Installation And Owner's Manual

Cast iron vented fireplace heater

Advertisement

The Classic Cast Iron Stoves
Installer: Leave this manual with the appli-
ance.
Consumer: Retain this manual for future refer-
ence.
WARNING: If the information in these in-
structions are not followed exactly, a fire or ex-
plosion may result causing property damage,
personal injury or loss of life.
— Do not store or use gasoline or other flamma-
ble vapors and liquids in the vicinity of this or
any other appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
If you cannot reach your gas supplier, call
the fire department.
— Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
15627-4-0806

INSTALLATION INSTRUCTIONS

OWNER'S MANUAL
AND
CAST IRON
VENTED FIREPLACE HEATER
MODEL
CIBV-30-20
EFFECTIVE DATE
AUGUST 2006
AVERTISSEMENT: Assurez vous de bien
suivre les instructions données dans cette notice
pour réduire au minimum le risque d'incendie
ou d'explosion ou pour éviter tout dommage
matériel, toute blessure ou la mort.
— Ne pas entreposer ni utiliser d'essence ni
d'autres vapeurs ou liquides inflammables
dans le voisnage de cet appareil ou de tout au-
tre appareil.
— QUE FAIRE SI VOUS SENTEZ UNE ODEUR
DE GAZ:
Ne pas tenter d'allumer d'appareil.
Ne touchez a aucun interrupteur. Ne pas
vous servir des téléphones se trouvant
dans le bâtiment où vous vous trouvez.
Appelez immédiatement votre fournisseur
de gaz depuis un voisin. Suivez les instruc-
tions du fournisseur.
Si vous ne pouvez rejoindre le fournisseur
de gaz, appelez le service des incendies.
— L'installation et l'entretien doivent être as-
surés par un installateur ou un service
d'entretien qualifié ou par le fournisseur de
gaz.
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for Empire Comfort Systems pmn

  • Page 1: Installation Instructions

    The Classic Cast Iron Stoves Installer: Leave this manual with the appli- ance. Consumer: Retain this manual for future refer- ence. WARNING: If the information in these in- structions are not followed exactly, a fire or ex- plosion may result causing property damage, personal injury or loss of life.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS SECTION PAGE Important Safety Information ...3 Safety Information for Users of LP Gas ...4 Introduction ...5 Specifications ...6 Gas Supply ...7 Clearances ...8 Appliance Hardware Package ...9 Assembly of Stove Casting ... 9-12 Optional Stone Inlay Installation ...12 Wire Channel Installation ...13 Log Placement ...13 Operating Guidelines ...14...
  • Page 3: Important Safety Information

    IMPORTANT SAFETY INFORMATION DO NOT OPERATE THIS APPLIANCE WITHOUT FRONT PANEL INSTALLED. • Due to high temperatures, the fireplace heater should be located out of traffic and away from furniture and draper- ies. • Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition.
  • Page 4: Safety Information For Users Of Lp Gas

    SAFETY INFORMATION FOR USERS OF LP-GAS Propane (LP-Gas) is a flammable gas which can cause fires and explosions. In its natural state, propane is odorless and colorless. You may not know all the following safety precautions which can protect both you and your family from an accident. Read them carefully now, then review them point by point If a gas leak happens, you should be able to smell the gas because of the odorant put in the LP-Gas.
  • Page 5: Introduction

    Introduction Always consult your local Building Department regarding regulations, codes or ordinances which apply to the installation of a vented fireplace heater. Instructions to Installer 1. Installer must leave instruction manual with owner after installation. 2. Installer must have owner fill out and mail warranty card supplied with heater.
  • Page 6: Specifications

    Model Input BTU/HR (KW/H) Maximum BTU/HR (KW/H) Minimum Height Width Depth including diverter Gas Inlet Size Draft Diverter Collar Floor to top of collar on vertical position of Draft Diverter Floor to center of collar on horizontal position of Draft Diverter Stove Casting (Must be ordered with Firebox) CIFB-1...
  • Page 7: Gas Supply

    Consult the current National Fuel Gas Code, ANSI Z223.1 CAN/ CGA-B149 (.1 or .2) installation code. Recommended Gas Pipe Diameter Pipe Length Schedule 40 Pipe Inside Diameter Nat. L.P. 0-10 feet 1/2” 3/8” 0-3 meters 12.7mm 9.5mm 10-40 feet 1/2” 1/2”...
  • Page 8: Clearances

    Clearances: When facing the front of the fireplace heater the minimum clearances to combustible construction (material) are the following: Open in front to provide service, access, and clearance to construction. Top of appliance (ceiling) Draft Diverter to Rear Wall Side Wall Heater Corners (45°...
  • Page 9: Appliance Hardware Package

    APPLIANCE HARDWARE PACKAGE Figure 5 ASSEMBLY OF STOVE CASTING Assembly of Stove Casting (Figures 6, 7, 8, 9, 10, 11 and 12) Attention: Included in the hardware package are (8) 1/4" inside diameter washers. A 1/4" washer may be used with a 1/4-20 x 3/8" bolt when assembling the stove casting parts.
  • Page 10: Assembly Of Stove Casting

    ASSEMBLY OF STOVE CASTING 5. Align the 3/8" hole at the top of the leg with the 3/8" hole in the leg pad. Attention: For proper positioning of the leg to the leg pad the (2) 1-1/2" top edges of the leg must be placed flush and parallel to the (2) edges on the leg pad.
  • Page 11 8. Position the completed portion of the casting in the approximate location for installation as the completed assembly will be heavy. 9. Refer to Figure 8, remove protective packing foam from casting front and window. Remove the (1) 3/4" bolt and (1) 1/4"...
  • Page 12: Optional Stone Inlay Installation

    ASSEMBLY OF STOVE CASTING (continued) 12. The following procedure will provide a snug fit between the casting front and the casting sides. Grasp the right, front leg, push inward on the leg in order to provide a snug fit between the casting front and the casting side.
  • Page 13: Wire Channel Installation

    WIRE CHANNEL INSTALLATION The ON/OFF/REMOTE switch with harness is factory installed into the switch box. After the appliance housing is installed into the casting the wire channel can be installed. 1. Attach switch box on the left side of rear cover with (2) 10 x 1/2"...
  • Page 14: Operating Guidelines

    Before operating this heater, please review the safety warnings pages at the beginning of this manual and those precautions and warnings listed below. 1. Know what type of ignition system this model has (standing pilot) and follow the applicable SAFETY and LIGHTING instructions.
  • Page 15: Venting

    Venting 1. Flue pipe must be as large as the flue collar on the draft diverter. 2. Maintain an upward slope of at least 1/4 inch (6mm) per foot of horizontal run. 3. Run flue pipe as directly as possible with a minimum of elbows.
  • Page 16: Lighting Instructions

    FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand.
  • Page 17: Pilot Flame Characteristics

    PILOT FLAME CHARACTERISTICS Figure 16 shows a correct pilot flame pattern. The correct flame will be blue and will extend beyond the thermopile. The flame will surround the thermopile just below the tip. A slight yellow flame may occur where the pilot flame and main burner flame meet.
  • Page 18: Wiring

    CIBV-30 ON/OFF/REMOTE Switch CIBV-30 is equipped with an ON/OFF/REMOTE switch which is located on the wire channel. A wire harness is attached to the ON/OFF/REMOTE switch. The red, black and green (wires) female push-ons attach to the ON/OFF/REMOTE switch. At the opposite end of the wire harness, the black and green (wires) female push- ons attach to the gas valve.
  • Page 19: Maintenance

    Installation of Remote Receiver (Figure 20) 1. Attach, from left to right, the slide-on cover plate onto the remote receiver. ON will be to the top and OFF will be to the bottom on the slide-on cover plate. 2. Push the receiver slide button onto the receiver slide switch. Reverse installation of the slide button if it is off center.
  • Page 20: Maintenance

    General Glass Information Only glass approved for use in Empire Comfort Systems, Inc. fireplaces may be used for replacement. The glass replacement should be done by a licensed or qualified service person.
  • Page 21: Troubleshooting

    With proper installation and maintenance, your new Vented Fireplace Heater should provide years of trouble-free service. If you do experience a problem, refer to Trouble Shooting Guide below. This guide will assist a qualified service person in the diagnosis of problems and the corrective action to be taken. 1.
  • Page 22: How To Order Repair Parts

    Do not order bolts, screws, washers or nuts. They are standard hardware items and can be purchased at any local hardware store. Shipments contingent upon strikes, fires and all causes beyond our control. Empire Comfort Systems, Inc. Nine Eighteen Freeburg Ave. Belleville, Illinois 62222-0529 Index...
  • Page 23: Parts View For Cibv-30-20

    PARTS VIEW FOR CIBV-30-20 15627-4-0806 Page 23...
  • Page 24: Parts List For Stove Casting

    PARTS LIST FOR STOVE CASTING PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide. Index Part Number Description *CI-006 WINDOW RETAINING TAB R-3948 WINDOW (BLACK PAINT) R-3688 WINDOW (BLACK ENAMEL) R-3696 WINDOW (SAND ENAMEL) R-3704 WINDOW (GREEN ENAMEL) R-3712...
  • Page 25: Parts View For Stove Casting

    PARTS VIEW FOR STOVE CASTING Models: CIFB-1, CIPB-1, CIPG-1, CIPS-1, CIPN-1, CIPR-1 15627-4-0806 Page 25...
  • Page 26: Optional Blower Installation Instructions

    OPTIONAL BLOWER INSTALLATION INSTRUCTIONS Installing Optional CIB-2 Blower 1. Loosen, but do not remove, (4) hex-head screws located on the exterior, bottom of the appliance. 2. Position the blower assembly at the rear of the appliance. The blower assembly has (4) keyholes for attachment to the exterior, bottom of the appliance.
  • Page 27 Cleaning The blower wheel will collect lint and could require cleaning once a year. If the air output decreases or the noise level increases, it indicates a dirty wheel. Blower Motor The blower motor does not have oiling holes. Do not attempt to oil blower motor.
  • Page 28 Empire Comfort Systems, Inc. Nine Eighteen Freeburg Ave. Belleville, Illinois 62222-0529 Page 28 PH: 1-800-851-3153 PH: 1-618-233-7420 FAX: 1-800-443-8648 FAX: 1-618-233-7097 E-MAIL: info@empirecomfort.com WEB SITE: www.empirecomfort.com 15627-4-0806...

This manual is also suitable for:

Cibv-30-20

Table of Contents