F2Rc/F2Fc036; F2Rp/F2Fp042 F2Fp048; G2Fd036(S,H)17; G2Fd042(S,H)21 - York 018-060 Technical Manual

Split-system air conditioners 10 seer 1.5 thru 5 nominal tons, 1 ph/3 thru 7.5 nominal tons, 3 ph
Table of Contents

Advertisement

036-21122-002 Rev. B (0103)
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO.
INDOOR COIL MODEL NO.
CONDENSER
ENTERING AIR
TEMPERATURE
75
85
95
105
115
125
NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature.
1 Phase
Air Handler
Coil
N1AHB1206

G2FD036(S,H)17

N1AHB1206
G2FD046(S,H)17

F2RC/F2FC036

F2RP/F2FP036
F2RP/F2FP042
G1FA036S14
G1FA048S17
G1FA048S21
G1HD036
G2FD046(S,H)17
G1HD048
G1NA036S17J
G1NA036S21C
G1UA036S14
G1UA036S17,21
G1UA048S17
G1UA048S21
G2FD035(S,H)14
G2FD036(S,H)17
G2FD036(S,H)21

G2FD042(S,H)21

14
HBBA-F036S, HABA-(T,W)036S
G1FA036S17,21
ID CFM
1150
ID DB (°F)
85
80
ID WB (°F)
72
67
T.C.
38.3
36.1
S.C.
24.0
23.7
K.W
3.19
3.14
T.C.
36.9
34.6
S.C.
24.2
23.7
K.W
3.45
3.39
T.C.
35.5
33.2
S.C.
24.3
23.6
K.W
3.71
3.63
T.C.
33.2
30.4
S.C.
23.7
22.5
K.W
3.97
3.84
T.C.
31.0
27.6
S.C.
23.1
21.3
K.W
4.22
4.06
T.C.
28.7
24.8
S.C.
22.5
20.2
K.W
4.47
4.28
T.C.
S.C.
KW
1.01
1.00
1.00
1.02
1.02
1.00
1.00
0.86
1.00
1.02
1.01
1.00
1.02
1.01
1.01
1.00
1.00
1.00
1.04
1.04
1.01
1.07
1.07
1.04
1.02
1.02
1.05
1.02
1.02
1.00
1.04
1.04
1.05
1.02
1.02
1.01
1.02
1.02
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.04
1.04
1.01
1.07
1.07
1.04
0.99
0.99
0.99
1.01
1.00
1.00
1.01
1.00
1.00
1.02
1.02
1.00
1250
70
85
80
57
72
67
34.4
37.9
36.3
24.0
24.1
24.5
3.09
3.23
3.20
32.2
36.9
34.9
22.9
24.7
24.6
3.30
3.50
3.44
30.0
35.8
33.6
21.9
25.4
24.9
3.52
3.76
3.69
26.7
33.4
30.8
20.7
24.5
23.6
3.71
4.02
3.91
23.5
31.1
28.2
19.6
23.9
22.6
3.90
4.29
4.13
20.2
28.9
25.6
18.4
23.2
21.6
4.09
4.56
4.35
3 Phase
Air Handler
Coil
N1AHB1246
G2FD036(S,H)17
N1AHB1246
G2FD046(S,H)21
F2RC/F2FC036
G1FA048S21
G1NA036S17J
G1NA036S21C
G1UA036S17,21
G1UA048S21
G2FD036(S,H)17
G2FD036(S,H)21
1350
70
85
80
57
72
67
34.6
38.0
36.4
24.7
24.7
25.3
3.14
3.26
3.23
32.6
37.0
35.2
23.9
25.3
25.5
3.36
3.53
3.49
30.4
36.0
34.0
23.6
26.0
25.6
3.58
3.80
3.75
27.2
33.6
31.3
21.9
25.4
24.6
3.77
4.06
3.96
24.2
31.3
28.5
20.7
24.8
23.7
3.94
4.33
4.18
21.1
29.0
25.7
19.6
24.2
22.7
4.11
4.60
4.40
T.C.
S.C.
1.00
1.00
1.02
1.02
1.00
0.86
1.07
1.07
1.02
1.02
1.02
1.02
1.00
1.00
1.07
1.07
1.01
1.00
1.01
1.00
Unitary Products Group
70
57
34.9
25.2
3.18
33.0
24.8
3.40
31.0
24.4
3.62
27.7
23.0
3.81
24.4
21.6
4.00
21.0
20.2
4.19
KW
0.98
1.00
1.00
1.04
1.01
1.00
1.00
1.04
1.00
1.00

Advertisement

Table of Contents
loading

Table of Contents