0
Two-wire Light Plug Connector
Bellmouth Nut
Light Switch
Capacitor
Multi-wire Plug
Connector
Reverse Switch
Figure 0 - Removing the wiring harness
installing the wiring harness
Refer to Figure 31.
1.
Insert the pull chain and fan pull chain switch through the
round opening on the side of the switch housing. Thread
the bellmouth nut over the pull chain and hand tighten the
bellmouth nut.
2.
Reattach the patented breakaway connector to the end of the
pull chain.
3.
Insert the reversing switch into the square hole on the side of
the switch housing. Install and tighten the two screws you
removed previously from the other switch housing.
4.
Carefully place the capacitors in the switch housing.
Two-wire Light Plug Connector
Capacitor
Housing
Assembly
Screw
Reverse
Switch
Multi-wire Plug Connector
Figure  - Reinstalling the wiring harness
installing the lower switch housing
1.
Connect the upper plug connector from the motor to the
lower plug connector in the lower switch housing assembly.
See Figure 28.
NOTE: Both plug connectors are polarized and will only fit
together one way. Make sure that both connectors are properly
aligned before connecting them together. Incorrect connection
could cause improper operation and damage to the product.
41865-01 01/15/2007
Bellmouth Nut
Fan Speed
Switch
Capacitor
Housing As-
sembly Screw
Fan Speed
Switch
Capacitor
2.
Place the lower switch housing assembly over the upper switch
housing. Align the side screw holes in the upper and lower
switch housings. Attach the lower switch housing to the up-
per switch housing with three #6-32 x 3/8" housing assembly
screws. See Figure 28.

operating your ceiling fan

1.
Turn on electrical power to the fan.
2.
The fan pull chain controls power to the fan. The pull chain has
four settings in sequence: High, Medium, Low and Off.
Pull the chain slowly to change settings.
Release slowly to prevent the chain from recoiling into the
blades.
The chain uses a breakaway connector that separates if the
chain is jerked. If this happens, simply reinsert the chain
into the connector.
3.
The light pull chain controls power to the light. The pull chain
has two settings: On and Off.
4.
Ceiling fans work best by blowing air downward (counterclock-
wise blade rotation) in warm weather to cool the room with a
direct breeze. In winter, having the fan draw air upward (clock-
wise blade rotation) will distribute the warmer air trapped at
the ceiling around the room without causing a draft. Refer to
Figure 32.
Figure  - Air flow patterns
To change the direction of air flow, turn the fan off and let it
come to a complete stop. Slide the reversing switch on the fan
to the opposite position as shown in Figure 33. Restart fan.
Fan Pull