STARTING COLD ENGINE

• Check unit for loose nuts, bolts and screws daily.
• Recoil starter: Use short pulls - only 1/2-2/3 of rope length for
starting. Do not allow the rope to snap back in. Always hold the unit
firmly.
• Rotate throttle handle downward to a comfortable operating position.
1. Throttle Lever
Move throttle lever (A) to START/IDLE DETENT position.
2. Choke
Move choke (B) to "Cold Start" (
3. Purge Bulb
Pump purge bulb (C) until fuel is visible and flows freely in the
clear fuel tank return line. Pump bulb an additional 4 or 5 times.
4. Recoil Starter
Pull recoil starter handle (D) until engine fires, or maximum 5 pulls.
5. Choke
Move choke (B) to run (
engine.
NOTE
If engine does not start after 5 pulls, repeat instructions 2-5.
NOTE
Allow engine to warm up before use.
) position.
) position and if necessary, restart
A
B
C
D