OPERATION

Starting Cold Engine

1.
Stop Switch
Move stop switch (A) away from
the STOP position.
Note: Engine will not run if
safety switch is not
activated.
2.
Throttle Position Lever
Move throttle position lever (B)
midway between idle and full
throttle positions.
3.
Choke
Move choke (C) to COLD START
(
) (closed) position.
4.
Purge Bulb
Pump purge bulb (D) until fuel is
visible and flows freely in the
clear fuel tank return line.
Recoil starter: Use short pulls - only 1/2 to 2/3 of rope for starting. Do
not allow the rope to snap back in. Always hold the unit firmly.
5.
Recoil Starter
Place the unit on a flat, clear
area. Firmly grasp throttle
handle (E) with left hand and
rapidly pull recoil starter handle
(F) until engine fires, or
maximum 5 pulls.
6.
Choke
Move choke lever to RUN
position (
restart engine.
22
), and if necessary,
A
D
C
E
F
©10/2019 ECHO Inc.
PB-2520
B
X7501190003