High Altitude Adjustment - Jøtul GI 450 DV Katahdin Installation And Operation Instructions Manual

Direct vent gas fireplace insert
Table of Contents

Advertisement

S S S S S ympt
ympt
ympt
oms o
oms o
f inc
f inc
orr
orr
orrec ec ec ec ect t t t t g g g g gas pr
ymptoms o
ympt
oms o
oms of inc
f inc
f incorr
orr
Insuf
Insuf
Insufficien
Insuf
Insuf
ficien
ficien
ficien
ficient t t t t g g g g gas pr
as pr
as pr
as pressur
as pr
essure: e: e: e: e:
essur
essur
essur
• Small pilot flame which can result in insufficient
millivolts.
• Little variation in flame picture between HI and LO
settings.
• Insufficient gas to support more than one appliance
causing nuisance outages or gas surges.
E E E E E x x x x x c c c c c essiv
essiv
essiv
essiv
essive g
e gas pr
e g
e g
e g
as pressur
as pr
as pr
as pr
essur
essur
essur
essure: e: e: e: e:
• Permanent damage to valve causing complete
appliance shut down.
• Too large a pilot flame resulting in over heating of
the power generator causing shut down.
• Sooting due to impingement and/or incorrect fuel to
air mix.

High Altitude Adjustment

When installing GI 450 Katahdin insert at high altitude
(above 2000'), it is necessary to compensate for the
thinner air (less volume of air per cubic foot). Higher
altitudes affect the atmospheric pressure and heat
value of gaseous fuels. The lower oxygen content in the
air and the lower gas viscosity require the use of a
different orifice to achieve efficient, clean combustion
at the burner tube.
In In In In In the U
the U
the U.S .S .S .S .S. . . . .
the U
the U
THE DERATING KIT MUST BE INSTALLED BY AN AUTHO-
RIZED SERVICE TECHNICIAN IN ACCORDANCE WITH THE
MANUFACTURER'S INSTRUCTIONS AND ALL CODES AND
REQUIREMENTS OF THE AUTHORITY HAVING JURISDIC-
TION. THE INFORMATION STICKER MUST BE FILLED OUT
BY THE INSTALLER AND ADHERED TO THE APPLIANCE AT
THE TIME OF THE CONVERSION. THE QUALIFIED SERVICE
AGENCY PERFORMING THIS WORK ASSUMES RESPONSI-
BILITY FOR THIS DERATING.
In C
In C
In C
In Canada
In C
anada
anada
anada
anada
This unit has been tested for installation at high alti-
tudes in accordance with Canadian test standard CAN/
CGA-2.17.THE DERATING SHALL BE CARRIED OUT IN
ACCORDANCE WITH THE REQUIREMENTS OF THE
PROVINCIAL AUTHORITIES HAVING JURISDICTION AND
IN ACCORDANCE WITH THE REQUIREMENTS OF THE
CAN1-B-149.1 AND .2 INSTALLATION CODE.
14
as pr
as pr
essur
essur
e include:
e include:
as pressur
as pr
essure include:
essur
e include:
e include:
HIGH ALTITUDE INSTALLATIONS:
2000 ft. to 4500 ft. installations (or 610m - 1370m)
See Table 1.
For high altitude installations consult the local gas
distributor or the authority having jurisdiction for
proper rating methods. If the installer must convert the
unit to adjust for varying altitudes, the information label
must be completed by the installer and affixed to the
appliance at the time of the conversion. See fig. 14.
Derating procedure
1. 1. 1. 1. 1. To derate this unit, install the appropriate orifice per
the High Altitude Chart.
2. 2. 2. 2. 2. Remove the two ¼" hex head screws that hold the
burner tube/log support to the bottom of the insert.
3. 3. 3. 3. 3. Remove the burner tube/log support to expose the
main burner orifice.
4 4 4 4 4 . . . . . Remove the orifice and replace with the appropriate
one from the high altitude kit.
5 5 5 5 5 . . . . . Be sure to attach the high altitude conversion sticker
provided with the kit to the rating plate on the
appliance. See figure 14.
6. 6. 6. 6. 6. It may be necessary to adjust the air shutter on the
burner tube. See the AIR SHUTTER/FLAME APPEAR-
ANCE section of this manual for more details.
ORIFICE
GAS TYPE
SIZE
NATURAL
#31
GAS
#51
PROPANE
NATURAL
#32
GAS
PROPANE
#52
Table 1. High Altitude Orifice Chart.
THIS APPLIANCE HAS BEEN CONVERTED FOR USE
AT AN ALTITUDE OF ______________________
Orifice Size: _______ Manifold Press: ________
Input, BTU/Hr: ________ Fuel Type: _________
Date of Conversion: ______ / _______ / ______
Figure 14. High Altitude Conversion Notice Label
JØTUL
ELEVATION
PART NO.
0 - 2000'
045026
(0 - 619m)
0 - 2000'
045027
(0 - 619m)
2001'- 4500'
045024
(611 - 1170m)
2001'- 4500'
045025
(611 - 1170m)