Humidity Sensor - GE SCA1000 Technical Service Manual

Table of Contents

Advertisement

Screws
Screws
4. Remove 2 screws and the thermistor.

Humidity Sensor

1. Remove the outer case (see procedure).
2. Disconnect the humidity sensor wiring from
the PCB.
Screws
Screws
3. Remove 7 screws securing the damper duct
to the unit and lift to provide access to the
humidity sensor.
Thermistor
Thermistor
GEA00988
GEA01006
Cavity TCO
Cavity TCO
Cavity TCO
Screw
Screw
Screw
4. Remove 2 screws and the humidity sensor.
– 38 –
Humidity Sensor
Humidity Sensor
Humidity Sensor
Screws
Screws
Screws
GEA01007