Control Panel

1. Remove the grille (see previous procedure).
2. Remove 1 screw from the top center of the
control panel.
3. Open the oven door.
4. Slide the panel up to release the upper locking
tabs and tilt the top of the panel out.
Wiring Harness
Wiring Harness
Connectors
Connectors
5. Pull the bottom of the panel out and slide the
panel down to release the lower locking tab.
6. Disconnect wiring harness connectors and
remove the control panel.

Door Interlock Switches

1. Remove the control panel (see procedure).
Screws
Screws
Screws
2. Remove 2 screws and pull the interlock latch
board out to access the wire leads.
Locking Tabs
Locking Tabs
GEA00989
GEA00994
Primary
Primary
Primary
Interlock
Interlock
Interlock
Interlock
Monitor
Monitor
Monitor
Door Sensing
Door Sensing
(Secondary Interlock)
(Secondary Interlock)
3. Remove the wire leads from the switches and
remove the interlock latch board.

Main PCB

Note: Voltage compensation test must be
performed when main PCB is replaced (refer to
test on page 50).
1. Remove the control panel (see procedure)
and place face down on a protected surface.
The main PCB is attached to the back of the
control panel.
Catch
Catch
Connectors
Connectors
– 29 –
Wire
Wire
Wire
Leads
Leads
GEA01022
Screws
Screws
Main
Main
PCB
PCB
Locking
Locking
Tabs
Tabs
GEA00990