High Voltage Transformer; Magnetron; Damper Assembly - GE SCA1000 Technical Service Manual

Table of Contents

Advertisement

High Voltage Transformer

1. Remove the control panel (see procedure).
2. Remove the low voltage transformers (see
procedure).
3. Disconnect the high voltage transformer
wiring.
Screws
Screws
4. Remove the right cooktop filter.
5. Access and remove 4 screws securing the
high voltage transformer.
6. Remove the transformer.

Magnetron

1. Remove the control panel (see procedure).
2. Remove the low voltage transformers (see
procedure).
3. Remove the high voltage transformer (see
procedure).
4. Disconnect the wiring from the magnetron and
the magnetron TCO.
High Voltage
High Voltage
Transformer
Transformer
Transformer
GEA01015
GEA00987
– 31 –
Magnetron
Magnetron
TCO
TCO
Screws
Screws
5. Remove 4 screws and the magnetron.

Damper Assembly

1. Remove the control panel (see procedure).
2. Disconnect the damper motor wire leads.
3. Remove 3 screws and lift the damper motor
assembly straight up to disengage the damper
door and remove.
Note: Be certain linkage to damper outlet door is
connected when reassembling.
Damper Outlet
Damper Outlet
Damper Outlet
Door Linkage
Door Linka
Door Linkage
Damper Door
Damper Door
Damper Door
Sensing Switc
Sensing Switch
Sensing Switch
Note: Photo shows casing removed for
clarity.
Magnetron
Magnetron
Screws
Screws
GEA00997
Mounting
Mounting
Mounting
Screws (3)
Screws (3)
ws (3)
GEA01130