5-8. RAS-18NKDX5-T / RAS-18N2AX-T

0.39 m
(Connecting pipe)
∅15.88
O.D.:15.88 mm
P
Packed valve
Accumulator
PH290X2C-4FT1
Compressor
50 Hz
Standard
Cooling
High temperature
Low temperature
Note : Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor.)
Cross flow fan
(∅15.88)
Condenser
Propeller fan
Outdoor unit
Standard
pressure P
(MPaG)
0.52
0.62
0.38
T
Indoor unit
Evaporator
Surface temp. of heat
exchanger interchanging
pipe T (°C)
11.0
14.7
3.0
− 14 −
FILE NO. SVM-06010
0.49 m
(Connecting pipe)
∅6.35
O.D.:6.35 mm
Packed valve
(∅6.35)
Capillary tube
∅2.0x1000 s
Refrigerant
R22 1.50 kg
Mark (
) means check points of Gas Leak
Ambient temp.
conditions DB/WB
Fan speed
(°C)
(indoor)
Indoor
High
27/19
High
32/23
Low
21/15
Outdoor
35/24
43/26
21/15