Outdoor Unit (Ras-18N2Ax-T) - Toshiba RAS-24NKHD-E5 Service Manual

Split wall type
Table of Contents

Advertisement

4-3. Outdoor Unit (RAS-18N2AX-T)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
5
Magnetic contactor
4-4. Indoor Unit (RAS-24N2AX-T)
No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
5
Magnetic contactor
Type
Output (Rated) 1500 W, 2 poles, 1 phase, 220 – 240 V, 50 Hz
PH290X2C-4FT1
Winding resistance (Ω)
(at 20°C)
Output (Rated) 42 W, 4 poles, 1 phase, 220 – 240 V, 50 Hz
FG-240-42A
Winding resistance (Ω)
(at 20°C)
451305L
AC 450 V, 3.0µF
RA44B356U0215S AC 440 V, 35µF
CLK-26J
220 – 240 V, 50 Hz
Type
Output (Rated) 2200 W, 2 poles, 1 phase, 220 − 240 V, 50 Hz
PH400X3CS-4KT1 Winding resistance (Ω )
(at 20 °C)
Output (Rated) 42 W, 4 poles, 1 phase, 220 − 240 V, 50 Hz
FG-240-42A
Winding resistance (Ω )
(at 20 °C)
AC 450 V, 3.0µF
451305L
AC 440 V, 50µF
RS44B506U0218S
220 − 240 V, 50 Hz
A35
− 11 −
FILE NO. SVM-06010
Specifications
C-R
1.71
Red-Black
White-Black
128
Specifications
C-R
1.13
Red-Black
128
C-S
3.09
126
C-S
2.10
White-Black
126

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents