Having A Problem - Chamberlain LiftMaster Security+ 1210EM FS2 Owner's Manual

Table of Contents

Advertisement

Available languages

Available languages

Care of Your Opener
LIMIT AND FORCE ADJUSTMENTS
Weather conditions may cause
some minor changes in door
operation requiring some
readjustments, particularly
during the first year of operation.
Pages 29 and 30 refer to the
limit and force adjustments.
Only a screwdriver is required.
Follow the instructions carefully.
Repeat the safety reverse test
(page 31) after any
adjustment of limits or force.
MAINTENANCE SCHEDULE
Once a Month
• Manually operate door. If it is unbalanced or
binding, call a trained door systems technician.
• Check to be sure door opens and closes fully.
Adjust limits and/or force if necessary. (See pages
29 and 30.)
• Repeat the safety reverse test. Make any
necessary adjustments. (See page 31.)
Twice a Year
• Check chain tension. Disconnect trolley first. Adjust
if necessary. (See page 15.)
Once a Year
• Oil door rollers, bearings and hinges. The opener
does not require additional lubrication. Do not
grease the door tracks.
THE REMOTE CONTROL BATTERY
To prevent possible SERIOUS INJURY or DEATH:
• NEVER allow small children near batteries.
• If battery is swallowed, immediately notify doctor.
To reduce risk of fire, explosion or chemical burn:
• Replace ONLY with 3V2032 coin batteries.
• Do NOT recharge, disassemble, heat above 100°C
(212°F) or incinerate.
The lithium battery should
produce power for up to
5 years. To replace battery,
use the visor clip or
screwdriver blade to pry
open the case as shown.
Insert battery positive side
up (+).Dispose of old
battery properly.Replace the
battery with only 3V2032 coin cell batteries
NOTICE: To comply with FCC and/or Industry Canada (IC) rules, adjustment or
modifications of this receiver and/or transmitter are prohibited, except for changing
the code setting or replacing the battery. THERE ARE NO OTHER USER SERVICEABLE
PARTS. Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation
is subject to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
LIMIT CONTROLS
(Left side panel)
9
9
1
1
7
3
7
3
5
5
Kg
Kg
Open Force
Close Force
FORCE CONTROLS
(Back panel)
Battery
positive
side up (+)
34

Having a Problem?

1. The opener doesn't operate from either the
Door Control or the remote control:
• Does the opener have electric power? Plug a lamp
into the outlet. If it doesn't light, check the fuse box
or the circuit breaker. (Some outlets are controlled
by a wall switch.)
• Have you disabled all door locks? Review
installation instruction warnings on page 15.
• Is there a build-up of ice or snow under the door?
The door may be frozen to the ground. Remove
any restriction.
• The garage door spring may be broken. Have it
replaced.
• Repeated operation may have tripped the
overload protector in the motor. Wait 15 minutes
and try again.
2. Opener operates from the remote, but not from
the Door Control:
• Is the door control lit? If not, reverse the wires. If
the opener runs, check for a faulty wire connection
at the door control, a short under the staples, or a
broken wire.
• Are the wiring connections correct? Review
Installation Step 6.
3. The door operates from the Door Control, but
not from the remote control:
• Is the door push bar flashing? If your model has
the Lock feature, make sure it is off.
• Program the opener to match the remote control
code. (Refer to instructions on the motor unit
panel.) Repeat with all remotes.
4. The remote control has short range:
• Change the location of the remote control in your
car.
• Check to be sure the antenna on the side or back
panel of motor unit extends fully downward.
• Some installations may have shorter range due to
a metal door, foil backed insulation, or metal
garage siding.
5. Opener noise is disturbing in living quarters of
home:
• If operational noise is a problem because of
proximity of the opener to the living quarters, the
Vibration Isolator Kit 89LM can be installed. This
kit was designed to minimize vibration to the house
and is easy to install.