Please read this manual and the enclosed safety materials carefully!
Fasten the manual near the garage door after installation.
The door WILL NOT CLOSE unless the Protector System
properly aligned.
Periodic checks of the opener are required to ensure safe operation.
The model number label is located under the light lens on the left side panel
of your opener.
TM
Garage Door Opener
OWNER'S MANUAL
Model 1280-298
- 1/2 HP -
For Residential Use Only
The Chamberlain Group, Inc.
A DUCHOSSOIS ENTERPRISE
845 Larch Avenue
Elmhurst, Illinois 60126-1196
Complies with UL 325
Regulations effective
January 1, 1993
®
®
is connected and

Advertisement

Table of Contents
loading

Summary of Contents for Chamberlain 1280

  • Page 1 Regulations effective January 1, 1993 ® Garage Door Opener OWNER'S MANUAL Model 1280-298 - 1/2 HP - For Residential Use Only Please read this manual and the enclosed safety materials carefully! Fasten the manual near the garage door after installation.
  • Page 2: Table Of Contents

    Contents Page Contents Page A review of safety alert symbols ......2 The Protector ® System safety reversing sensor information....17 Safety information regarding garage door locks and ropes..............3 Install the safety reversing sensor ....18,19 Testing your garage door for sticking, binding Fasten door bracket (sectional door)....20 and balance ............3 Fasten door bracket (one-piece door) ....21...
  • Page 3: Safety Information Regarding Garage Door Locks And Ropes

    CAUTION WARNING To avoid damage to the garage door and An unbalanced garage door might not reverse when required and someone under the door opener, disable locks before installing and could be seriously injured or killed. operating the opener. Use a wood screw or nail to hold locks in the "open"...
  • Page 4: Illustration Of Sectional Door Installation

    Before you begin, survey your garage area to see whether any of the conditions below apply to your installation. SECTIONAL Door or ONE-PIECE Door with Track Installation FINISHED CEILING Support bracket & fastening hardware is required. Horizontal and vertical reinforcement See page 13.
  • Page 5: Carton Inventory

    Carton Inventory Your garage door opener is packaged in two cartons which contain all parts illustrated below. If anything is missing, carefully check the packing material. Parts may be "stuck" in the foam. Hardware is listed on page 4. SECURITY Passive Infrared SECURITY Remote Control...
  • Page 6: Assembly Section: Pages

    Assembly Section: Pages 6 - 7 ASSEMBLY STEP 1 CAUTION Attach the T-Rail To the Opener To fasten rail, use only those screws mounted in the top of the opener. Any other screws will cause serious damage to the opener. Washered Screw •...
  • Page 7: Attach Belt Cap Retainer

    ASSEMBLY STEP 3 WARNING Attach the Belt Cap Retainer Serious injury can result if fingers become entangled in moving opener sprocket. Attach sprocket cover securely. Never operate opener • Position the belt cap retainer over the opener while your hand is near the opener sprocket. sprocket so the two holes in cap align with the two holes in mounting plate.
  • Page 8: Installation Section: Pages

    Installation Section: Pages 8 – 23 Installation Step 1 WARNING Determine Header Bracket Location If the header bracket is not rigidly fastened to Installation procedures vary according to a structural support on the header wall or garage door types. Follow the instructions ceiling, the safety reverse system may not which apply to your door.
  • Page 9: One-Piece Door

    ONE-PIECE Door Without Track Read the Safety Instructions on page 8. They also apply to doors without tracks. Unfinished Header Wall Ceiling Vertical Centerline • Close the door and mark the inside vertical centerline of Structural Supports your garage door. Extend the line onto the header wall above door.
  • Page 10: Install The Header Bracket

    You can attach the header bracket either to the Installation Step 2 wall above the garage door, or to the ceiling. Follow the instructions which will work best for Install the Header Bracket your particular requirements. Fasten the Header Bracket to the Wall •...
  • Page 11: Attach The T-Rail To Header Bracket

    Installation Step 3 Attach the T-rail to the Header Bracket The Chamberlain Group, In • Position the opener on the garage floor below the header bracket. Use packing material as a Liftmaster Synchro Drive protective base. Header Wall Attach Tee Rail to Header B If the door spring is in the way you'll need help.
  • Page 12: Position The Opener

    Installation Step 4 CAUTION Position the Opener To prevent damage to steel, aluminum, Follow instructions which apply to your door fiberglass or glass panel doors, do not rest the type as illustrated. opener on the door without using a 2x4. SECTIONAL Door &...
  • Page 13: Hang The Opener

    Installation Step 5 WARNING Hang the Opener The opener could fall and injure someone if it is not properly secured. Fasten the opener securely to structural supports of the garage. Two representative installations are shown. Yours may be different. Hanging brackets should be angled, Figure 1, to provide rigid support.
  • Page 14: Install The Multi-Function Door Control Panel

    Installation Step 6 WARNING Install the Door Control DO NOT CONNECT TO LIVE ELECTRICAL WIRING. CONNECT ONLY TO 24 VOLT LOW VOLTAGE WIRES. CONNECTION TO LIVE WIRES OR HIGHER Locate the door control within sight of the door at a VOLTAGE MAY CAUSE SERIOUS INJURY FROM minimum height of 5 feet where small children cannot SHOCK, BURN OR ELECTROCUTION.
  • Page 15: Install The Lights And Lenses

    Installation Step 7 Install the Lights and the Lenses • Install a 75 watt maximum light bulb in each socket. The lights will turn ON and remain lit for approximately 4-1/2 minutes when power is connected. Then the lights will turn OFF. Lens Guide •...
  • Page 16: Electrical Requirements

    Installation Step 9 WARNING Electrical Requirements To prevent electrocution or fire , installation and wiring must be in compliance with local To reduce the risk of electric shock, your garage electrical and building codes. door opener has a grounding type plug with a third Do NOT use an extension cord, 2-wire adapter, grounding pin.
  • Page 17: The Protector

    The Protector ® System IMPORTANT INFORMATION ABOUT THE SAFETY REVERSING SENSOR WARNING Without a properly working safety reversing The safety reversing sensor must be connected sensor, persons (particularly children) could be and aligned correctly before the garage door injured or killed by a closing garage door. Read opener will move in the down direction.
  • Page 18: Install The Safety Reversing Sensor

    Figure 2 Installation Step 10 DOOR TRACK MOUNT (Right Side) Install the Safety Reversing Sensor Door Track INSTALLING THE BRACKETS Be sure power to the opener is disconnected. Indicator Install and align the brackets so the sensors will face light each other across the garage door, with the beam from 4 –...
  • Page 19: Mounting And Wiring The Safety Sensors

    MOUNTING AND WIRING THE SAFETY SENSORS Figure 5 • Slide a 1/4"-20x1/2" carriage bolt head into the slot Wing nut on each sensor. Use wing nuts to fasten sensors to brackets, with lenses pointing toward each other across the door. Be sure the lens is not obstructed by a bracket extension.
  • Page 20: Fasten Door Bracket (Sectional Door)

    Installation Step 11 CAUTION Fasten Door Bracket To prevent damage to steel, aluminum, Follow instructions which apply to your door fiberglass or glass panel doors, always type as illustrated below or on page 21. reinforce the inside of the door both vertically and horizontally with an angle iron.
  • Page 21: Fasten Door Bracket (One-Piece Door)

    All ONE-PIECE Door Installation Procedure Please read and comply with the warnings and reinforcement instructions on page 20. They apply to one-piece doors also. Header Wall Header 2x4 Support Bracket — Finished Ceiling — Horizontal and vertical reinforcement is Optional Door needed for lightweight garage doors Placement...
  • Page 22: Connect Door Arm To Trolley (Sectional Door)

    Installation Step 12 Connect Door Arm to Trolley Follow instructions which apply to your door type as illustrated below and on page 23. SECTIONAL Doors Only Make sure garage door is fully closed. Pull the emergency release handle to disconnect the outer trolley from the inner trolley.
  • Page 23: Connect Door Arm To Trolley (One-Piece Door)

    All ONE-PIECE Doors Assemble the Door Arm: • Fasten the straight and curved door arm sections Ring Door together to the longest possible length (with a 2 or Fastener Bracket 3 hole overlap). Nuts Lock 5/16"-18 Washers • With the door closed, connect the straight door arm 5/16"...
  • Page 24: Adjustment Section: Pages

    Adjustment Section: Pages 24 – 26 Adjustment Step 1 WARNING Adjust the UP and DOWN Limits Improper adjustment of the travel limits will Do not make any limit adjustments until the interfere with the proper operation of the safety Safety Reversing Sensors are completely reverse system.
  • Page 25: Force Adjustments

    Adjustment Step 2 WARNING Adjust the Force Too much force on the door will interfere with the proper operation of the safety reverse system. Force adjustment controls are located on the right The door might not reverse properly when panel of the opener. Force adjustment settings required and could seriously injure or kill regulate the amount of power required to open and someone under it.
  • Page 26: Test The Protector System

    Adjustment Step 3 WARNING Test The Protector ® System Without a properly working safety reversing sensor, persons (particularly children) could be • Press the remote control push button to open the seriously injured or killed if trapped by a closing door.
  • Page 27: Operation Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS WARNING WARNING To reduce the risk of severe injury or death to persons: 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. Do not permit children either to operate or to play with the opener. Keep remote control in a location inaccessible to children.
  • Page 28: Operation Of Your Opener

    Operation of Your Opener Activate the opener with any of the following: WARNING • The Remote Control Transmitter. Hold push button down until the door starts to move. • The Door Control. Hold push bar down until the door Weak or broken springs could allow an open starts to move.
  • Page 29: Receiver & Remote Control Programming

    Receiver & Remote Control Programming NOTICE: To comply with FCC rules, adjustment or modification of this WARNING receiver and/or transmitter are prohibited, except for changing the code setting or replacing the transmitter battery. THERE ARE NO OTHER USER SERVICEABLE PARTS. Children operating or playing with a garage door opener can injure themselves or others.
  • Page 30: Having A Problem

    Having a Problem? Situation Probable Cause & Solution The opener doesn't 1. Does the opener have electric power? Plug a lamp into the outlet. If it doesn't light, operate from either check the fuse box or the circuit breaker. (Some outlets are controlled by a wall switch.) the door control or 2.
  • Page 31 Having a Problem? (continued) Situation Probable Cause & Solution The door opens but 1. If the opener lights blink, check the safety reversing sensor. See page 19. won't close: 2. If the opener lights do not blink and it is a new installation, check the down force. See Adjustment Step 2, page 25.
  • Page 32: Repair Parts, Rail Assembly

    Repair Parts Rail Assembly Parts PART DESCRIPTION 1A995 Master link kit 41A3588-1 Belt pulley bracket 41B3869-1 Complete trolley assembly 109B33 Trolley clip 183B99 One-piece T-rail 41A3589-12 Full belt assembly 41B4103 Tensioner assembly 83A4 Rail grease Installation Parts PART DESCRIPTION 41C472-3 Passive Infrared Control Console 41A5056-3 3-Channel remote control housing...
  • Page 33: Repair Parts, Opener Assembly

    Repair Parts Opener Assembly Parts 18 19 (Down) LIMIT SWITCH ASSY. Brown Contact Wire Grey Wire Drive Gear Center Limit (Up) Yellow Contact Contact Wire KEY PART PART NO. NO. DESCRIPTION DESCRIPTION 41A4371 Belt cap retainer 30B363 Capacitor – 1/2 h.p. 41A4885-2 Gear and sprocket assy., 12A373...
  • Page 34: Accessories

    Accessories Available For Your Opener Outside Quick Release: Model 59LM Outside Keylock: Model 1702LM Required for a garage with NO Opens the garage door access door. automatically from outside when remote control is not handy. Model 1778LM 8 foot Complete Rail: SECURITY 3-Channel Model 973LM Remote Control:...
  • Page 35: Index

    Index Access Door/Outside Quick Release Accessory..................31, 34 Electrical Safety Warnings........................7, 16, 27 Garage Door Testing for balance, binding and sticking....................3, 24, 27 Determining high point of travel: Sectional door..............................8 One-piece door ..............................9 Disabling existing locks............................3, 7 Force controls Adjustment procedures.............................25 Problems that might require force adjustments ..................30, 31 Safety warnings ............................25, 27 Door hardware ..........................3, 7, 8, 14, 27, 28...
  • Page 36: How To Order Repair Parts

    1-800-528-2817 Service number for a list of dealers in your area. LIFT-MASTER GARAGE DOOR OPENER FIVE-YEAR LIMITED WARRANTY The Chamberlain Group, Inc. (“Seller”) warrants to the first retail purchaser of this product, for the residence in which this product is originally installed, that it will be free from any defect in materials and/or workmanship for a period of 60 full months from the date of purchase.

This manual is also suitable for:

1298Liftmaster 1280-298

Table of Contents