7
Cyclical printout defects (Figure 5.2- E )
Cycle
94.3 mm
49.6 mm
67.6 mm
44.0 mm
113 mm
57.8 mm
Note: After replacement of the ID unit, fuser unit or belt cassette unit, the corresponding counter
must be reset in the user maintenance mode.
41388601TH Rev.6
Defective Part
Image Drum
Developing Roller
Toner Supply Roller
Charge Roller
Fuser Roller
Transfer Roller
Solution
Replace the ID unit.
Replace the ID unit.
Replace the ID unit.
Replace the ID unit.
Replace the fuser unit.
Replace the belt cassette assembly.