PRODUCT FEATURES

GAS SPECIFICATIONS

Model
Fuel
DEB0NM
Nat.
DEB0PM
LP
DEB4NM
Nat.
DEB4PM
LP
DEB30NM
Nat.
DEB30PM
LP
DEB0NV
Nat.
DEB0PV
LP
DEB4NV
Nat.
DEB4PV
LP
DEB30NV
Nat.
DEB30PV
LP

GAS PRESSURES

Manual Regulator Pressure
Millivolt Regulator Pressure
Millivolt Pilot Regulator
Max. Gas Inlet Pressure
Min. Gas Inlet Pressure
NOTE: An external regulator is required to reduce supply
pressure to a maximum of 10.5" w.c. on Natural Gas sys-
tems operating at higher pressure.
NOTE: An external regulator is required to reduce supply
pressure to a maximum of 13.0" w.c. for LP systems.
44D0060
Max.Input Min. Input
Control
BTU/h
BTU/h
Manual
18,000
8,000
Manual
18,000
8,000
Manual
0,000
38,000
Manual
0,000
38,000
Manual
0,000
38,000
Manual
0,000
38,000
Millivolt
18,000
8,000
Millivolt
0,000
8,000
Millivolt
5,000
38,000
Millivolt
30,000
38,000
Millivolt
5,000
38,000
Millivolt
30,000
38,000
Natural
Propane (LP)
3.0" w.c.
10.0" w.c.
3.5" w.c.
10.0" w.c.
3.5" w.c.
n/a
10.5" w.c.
13.0" w.c.
5.0" w.c.
11.0" w.c.

IGNITION CONTROLS

Piezo ignitor allows ignition of the pilot without the
use of matches or batteries.
Manual control has three (3) positions:
OFF
- All gas to the gas logs is shut off at
the valve.
IGN
- Valve position to light/maintain a
standing pilot.
HI/LOW
- Variable position corresponding to
desired flame height.
Millivolt control has four (4) positions:
OFF
- All gas to the gas logs is shut off at
the valve.
IGN
- Valve position to light/maintain a
standing pilot.
ON
- Valve position to turn ON/OFF log
set with remote switch/thermostat.
LOW/HI
- Variable position to control flame
height (heat output).
PILOT/ODS
The gas log heater is fitted with a specially designed
safety pilot (ODS assembly) which senses the amount
of oxygen available in the room and shuts the gas log
heater off if the oxygen level begins to drop below
a satisfactory level. The pilot can only be relit when
adequate fresh air is available.

THERMAL GENERATOR

The millivolt gas log pilot is fitted with a millivolt
(thermopile) generator to provide power for remote
activation.
DEB Unvented Gas Logs