Product Features And Specifications - Monessen Hearth DST30 Installation And Operating Instructions Manual

Unvented gas log heater or
Table of Contents

Advertisement

PRODUCT FEATURES
NATURAL GAS
Milli-Volt Pressure
Regulator Pressure Setting:
Pilot Regulator:
Gas Inlet Pressure:
Model Number
DST30NV
PROPANE/LPG
Note: An external regulator is required to reduce supply pressure to a maximum of 13" w.c.
Milli-Volt Pressure
Regulator Pressure Setting:
Gas Inlet Pressure:
Model Number
DST30PV
IGNITION CONTROLS
Piezo ignitor allows ignition of the pilot without the use of matches or batteries.
Milli-Volt control has four (4) positions:
OFF -
All gas to the gas logs is shut off at the valve.
IGN -
Valve position to light/maintain a standing pilot.
ON -
Valve position to turn ON/OFF log set with remote, switch and/or thermostat.
HI/LOW -
Variable position to control flame height (heat output).
PILOT
The gas log heater is fitted with a specially designed safety pilot light (ODS assembly) which senses the amount of oxygen
available in the room and shuts the gas log heater off if the oxygen level begins to drop below a satisfactory level. The pilot
can only be relit when adequate fresh air is available.
THERMAL GENERATOR
The milli-volt gas log pilot is fitted with a milli-volt generator to provide power for remote activation.
6
SPECIFICATIONS
AND
3.5" w.c.
3.5" w.c.
Max. 10 1/2" w. c.
Min. 5" w.c.
Control
MILLI-VOLT
10" w.c.
Max. 13" w.c.
Min. 11" w.c.
Control
MILLI-VOLT
Gas Rate
Max BTU/Hr
Min BTU/Hr
38,000
Gas Rate
Max BTU/Hr
Min BTU/Hr
38,000
24,000
31,000
43D0122