Codes - Monessen Hearth DEB20 Installation And Operating Instructions Manual

Unvented gas log heater or vented decorative appliance
Table of Contents

Advertisement

DEB Unvented Gas Logs
The initial break-in operation should last two to three
hours with the burner at the highest setting. Provide
maximum ventilation by opening windows or doors to
allow odors to dissipate. Any odors remaining after this
initial break-in period will be slight and will disappear
with continued use.
0. Input ratings are shown in BTU per hour and are for
elevations up to ,000 feet. For elevations above ,000
feet, input ratings should be reduced 4 percent for each
1,000 feet above sea level. Refer to the National Fuel
Gas Code.
1. The appliance and its appliance main gas valve must
be disconnected from the gas supply piping system
during any pressure testing of that system at test pres-
sures in excess of 1/ psig (3.5 kPa).
. The appliance must be isolated from the gas supply
piping system by closing its equipment shutoff valve
during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/ psig
(3.5 kPa).
3. Do not use this room heater if any part has been under
water. Immediately call a qualified service technician
to inspect the room heater and to replace any part of
the control system and any gas control which has been
under water.
4. This appliance must not be used with glass doors in
the closed position. This can lead to pilot outages and
severe sooting outside the fireplace.
5. Never burn solid fuels in a fireplace where a unvented
room heater is installed.
6. Always have a fireplace screen in place when the
appliance is in operation and, unless other provisions
for combustion air are provided, the screen must have
an opening(s) for induction of combustion air.

CODES

Adhere to all local codes or, in their absence, the latest edition of THE NATIONAL FUEL GAS CODE
ANSI Z3.1 or NFPA54 which can be obtained from...
4
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
or
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 069
IMPORTANT SAFETY INFORMATION
Never connect unit to private (non-utility)
gas wells. This gas is commonly known
as wellhead gas.
Nous recommandons que nos
appareils de chauffage au gaz
soient installés et entretenus par
des professionnels qui ont été
accrédités aux È.U. par le National
Fireplace Institute ® (NFI) comme
étant des spécialistes du NFI en
matièred'appareils de chauffage
au gaz.
44D0060

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Deb24Deb30

Table of Contents