PRODUCT FEATURES
NATURAL GAS
NOTE: An external regulator is required to reduce supply pressure to a maximum of 10
natural gas systems operating at higher pressure.
MILLIVOLT
Regulator Pressure Setting: 3.5" w.c.
Pilot Regulator:
Gas Inlet Pressure:
PROPANE/LPG
Note: An external regulator is required to reduce supply pressure to a maximum of 13" w.c.
MILLIVOLT
Regulator Pressure Setting: 10" w.c
Gas Inlet Pressure:
IGNITION CONTROLS
Piezo ignitor allows ignition of the pilot without the use of matches or batteries.
Millivolt control has four (4) positions:
- All gas to the gas logs is shut off at the valve.
OFF
- Valve position to light/maintain a standing pilot.
IGN
- Valve position to turn ON/OFF log set with remote switch/thermostat.
ON
- Variable position to control flame height (heat output).
LOW/HI
PILOT/ODS
The gas log heater is fitted with a specially designed safety pilot (ODS assembly) which senses the amount of oxygen avail-
able in the room and shuts the gas log heater off if the oxygen level begins to drop below a satisfactory level. The pilot can
only be relit when adequate fresh air is available.
THERMAL GENERATOR
The millivolt gas log pilot is fitted with a Millivolt (thermopile) generator to provide power for remote activation.
6
SPECIFICATIONS
AND
3.5" w.c.
1
Max 10
/
" w.c.
2
Min. 5" w.c.
Max. 13" w.c.
Min. 11" w.c.
Model Number
Control
NB18NV
Millivolt
NB24NV
Millivolt
Model Number
Control
NB18PV
Millivolt
NB24PV
Millivolt
1
/
" W.C. on
2
Gas Rate
Max BTU/Hr
Min BTU/Hr
28,000
19,000
37,000
25,000
Gas Rate
Max BTU/Hr
Min BTU/Hr
27,000
22,000
36,000
28,000
81D0107