Indoor Fan Motor Control - Toshiba RAS-13SKV-E Service Manual

Split type indoor/outdoor unit
Hide thumbs Also See for RAS-13SKV-E:
Table of Contents

Advertisement

Item
2. Indoor fan
<In cooling operation>
motor control
(This operation controls the fan speed at indoor unit side.)
The indoor fan (cross flow fan) is operated by the phase-
control induction motor. The fan rotates in 5 stages in
MANUAL mode, and in 5 stages in AUTO mode, respec-
tively. (Table 1)
COOL ON
Fan speed setup
AUTO
Ta
[ ˚C ]
+2.5
a
+2.0
b
+1.5
c
+1.0
d
+0.5
e
Tsc
Fan speed
level
COOL HEAT DRY
WF
UH
WE
H
UH
WD
UH
M+
WC
H
H
WB
M+
M
M+
WA
M
W9
M
L+
W8
L
W7
L+
L-
L+
W6
L
L
W5
L-
UL
L-
W4
UL
UL
W3
SUL
SUL
W2
SUL
W1
Operation flow and applicable data, etc.
MANUAL
Indication
L
L+
M
M+
H
Air volume AUTO
M+(WB)
*3
*3 : Fan speed = (M + –L) x 3/4 + L
*4 : Fan speed = (M + –L) x 2/4 + L
*4
*5
*5 : Fan speed = (M + –L) x 1/4 + L
(Linear approximation
L(W6)
from M+ and L)
(Table 1) Indoor fan air flow rate
RAS-10SKVR-E
RAS-13SKV-E
Fan speed
Air flow rate
Fan speed
(rpm)
(m3/h)
(rpm)
1210
571
1240
1210
571
1240
1170
546
1190
1120
515
1140
1040
465
1040
1000
440
100
960
415
960
870
359
870
850
347
850
760
291
760
760
291
760
700
253
700
650
222
650
500
129
500
500
129
500
(Fig. 1)
Fan speed
W6
(L + M) / 2
W9
(M + H) / 2
WC
(Fig. 2)
RAS-13SKVR-E
Air flow rate
Fan speed
Air flow rate
(m3/h)
(rpm)
(m3/h)
630
1280
614
630
1280
614
596
1230
583
563
1160
540
496
1070
484
469
1030
459
443
990
434
383
870
359
369
860
353
309
770
297
309
770
297
269
720
266
236
670
234
135
520
141
135
500
129
– 34 –
Description
* Symbols
UH
: Ultra High
H
: High
M+
: Medium+
M
: Medium
L+
: Low+
L
: Low
L-
: Low–
UL
: Ultra Low
SUL
: Super Ultra Low
* The fan speed broadly varies due
to position of the louver, etc.
The described value indicates one
under condition of inclining
downward blowing.
1) When setting the fan speed to L,
L+, M, M+ or H on the remote
controller, the operation is
performed with the constant
speed shown in Fig. 1.
2) When setting the fan speed to
AUTO on the remote controller,
revolution of the fan motor is
controlled to the fan speed level
shown in Fig. 2 and Table 1
according to the setup tempera-
ture, room temperature, and heat
exchanger temperature.
RAS-16SKV-E
RAS-16SKVR-E
Fan speed
Air flow rate
Fan speed
(rpm)
(m3/h)
(rpm)
1470
743
1510
1470
743
1510
1440
723
1480
1390
691
1430
1250
601
1280
1190
563
1220
1120
518
1150
970
421
1000
950
408
980
890
370
920
870
357
900
810
318
840
750
280
770
600
183
620
500
119
520
Air flow rate
(m3/h)
735
735
717
686
594
557
514
421
409
372
360
323
280
187
126

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents