Specifications Of Electrical Parts - Toshiba RAS-13SKV-E Service Manual

Split type indoor/outdoor unit
Hide thumbs Also See for RAS-13SKV-E:
Table of Contents

Advertisement

6. SPECIFICATIONS OF ELECTRICAL PARTS

6-1. Indoor Unit
Parts name
No.
13SKV-E
Fan motor
1
10SKVR-E,13SKVR-E
(for indoor)
16SKV-E, 16SKVR-E
2
Room temp. sensor (TA-sensor)
3
Heat exchanger temp. sensor (TC-sensor)
4
Louver motor
6-2. Outdoor Unit
Parts name
No.
1
Reactor
2
Outdoor fan motor
3
Suction temp. sensor (TS sensor)
4
Discharge temp. sensor (TD sensor)
5
Outside air temp. sensor (TO sensor)
6
Heat exchanger temp. sensor (TE sensor)
7
Terminal block (6P)
10SAVR-E, 13SAV-E
8
Compressor
13SAVR-E, 16SAV-E, 16SAVR-E
9
COIL FOR P.M.V.
10
Coil for 4-way valve
11
Compressor thermo
Type
MMF-240-20-4B
AFS-220-20-4AR
ICF-340-30-2B
( − )
(
)
MP24Z3T
Model name
CH-57
ICF-140-43-4R
(Inverter attached)
(Inverter attached)
(Inverter attached)
(Inverter attached)
DA89X1C-23FZ
DA111A1F-20F1
C12A-01-R
VHV
PW-2AL
– 20 –
Specifications
AC240/220V, 20W
AC240V, 20W
DC 340V, 30W
Ω
10k
at 25°C
10kΩ at 25°C
Output (Rated) 1W, 16 poles, DC12V
Rating
L = 10mH, 16A
DC140V, 43W
10k
(25°C)
62k
(20°C)
10k
(25°C)
10k
(25°C)
30A, AC600V
3-phases 4-poles 750W
DC12V
AC220-240V
OFF : 125±4°C, ON : 90±5°C

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents