Item
Operation flow and applicable data, etc.
Pressing [RESET] button starts the temporary opera-
10. Temporary
tion of [AUTO] operation. When keeping [RESET]
operation
button pressed for 10 seconds or more, the temporary
[COOL] operation is performed.
Filter lamp ON
NO
Did you press [RESET] button
for 3 seconds or more?
YES
Did you press [RESET] button
for 10 seconds or more?
NO
Switch to [AUTO RESTART] control.
11. Air
This function generates nagative ion while cleaning the air in the room.
purifying
If air purifier-ON signal is received while the air conditioner stops, the air purifier starts operation,
control
and if it is received while the air conditioner operates, the air conditioner and the air purifier start
RAS-10SKVR-E
operation.
13SKVR-E
The air ion generator operates linked with the air purifying operation.
16SKVR-E only
Present status
Stop
Air purifier only
Air conditioner
Joint use of AC and air purifier
Air purifying operation
AC + Air purifying operation
Sending air purifier-ON
1
Air conditioner stops
Operation lamp ON
Memory position
of louver/COOL
Fan ON
Air purifier ON
Air purifying operation
YES
Press RESET button.
NO
Temporary [AUTO] operation
YES
Temporary [COOL] Operation
Operation button
PURE button
Air purifier
Stop (All)
AC + Air purifier
AC operation
Louver*1
Cooling position
Follows to AC operation
,
2
1
2
Air conditioner operates
Start of air purifier-ON
*1
Air conditioner +
air purifier operate
*2
Air conditioner
AC operation*
AC + Air purifier
All stop
All stop
Fan speed *2
AUTO, L, L+, M, M+, H
Follows to AC operation
3
Air purifier operates
Operation lamp OFF
Fan stop
Air purifier-OFF
Louver close
All stop
– 42 –
Description
1) When pressing [RESET] button, the
temporary [AUTO] operation starts.
2) When keeping [RESET] button pressed
for 3 seconds or more, Pi, Pi, Pi sound is
heard and [AUTO RESTART] control is
changed.
3) When keeping [RESET] button pressed
for 10 seconds or more, "Pi" sound is
heard and the temporary [COOL]
operation starts.
4) If the filter lamp goes on, press [RESET]
button to go off the filter lamp, and then
press [RESET] button again.
5) To stop the temporary operation, press
the button again.
* When the previous operation was the
operation of air conditioner + air purifier,
an operation of air conditioner + air purifier
starts by pushing AC button on the remote
controller.
(Operation of air conditioner + air purifier
is stored in memory.)
*1 Swing is available
*2 Fan speed is Fan Auto mode varies in
order, (M + 1) → (L) → (L–) → (SL).
Sending air purifier-OFF
,
3
4
Air conditioner +
Air purifier operate
Filter-OFF
Air conditioner operates
4

Hide quick links: