Installation - Preparation - Rinnai 0901 7042 Operation And Installation Manual

Timberflame compact
Table of Contents

Advertisement

Installation Information - Installation
Plinth Supplied with Heater
Air Slots
Preparation
1.
Position plinth into cavity or zero clearance box. The plinth correctly positions the heater
at the required level and the air slots at either end allow air to pass through and cool the
heater and/or zero clearance box
2.
Place the heater on a flat surface and remove the 3 screws holding the fascia (1) in place.
3.
Pull the bottom of the fascia forward until clear of the gas control buttons and lift up to
remove from frame.
4.
Remove the 2 screws holding the top glass retainer in place and lift off (2).
5.
Loosen the 2 screws holding the lower glass retainer in place and remove glass panel (3).
6.
Remove the barrel elbow from the gas connection bracket on the base of the heater at the
front right hand side (4). Make sure that the gas flare fitting and gas supply pipe are clean
and free from damage. Fit together ready for fitting to the heater.
7.
For installation into a masonry fireplace, the foam strips (5) must be attached to the
heater to provide a seal around the fireplace. If this does not provide an adequate seal an
alternative must be used.
8.
Insert the heater into the cavity on top of the plinth, taking care when inserting the gas
supply tube.
9.
There are 4 levelling screws at the base of the heater held in place with locknuts. If the
heater does not sit flat when in place it may be necessary to adjust these. The front screws
are accessible with the front of the heater removed. If adjustment of the rear feet is
required, the burner assembly and gas control will need to be removed (6).
10.
Once the heater is sitting flat attach it to the wall using the 4 holes (2 per side) on the front
flanges.
Rinnai New Zealand
Air Slots
1
2
7
10
3
Compact Op/Install Manual: 10170-C 02-09
15
5
11
6
8
9
4