Olivetti PR2 E Service Manual page 79

Hide thumbs Also See for PR2 E:
Table of Contents

Advertisement

This calibration sets the distance between the form TOF and the first print line.
The adjustment can only be activated if the "TOP MARGIN PR40 LIKE" parameter in the PR40+
emulation setup was set to "Nu.
Proceed as follows to perform this calibration:
1. Power on the printer with its cover open and while holding down the three buttons on the console.
2. Wait for the audible signal indicating that the printer has switched into the calibration and adjustment
procedures.
3. Press the Local button and then wait for the printer to complete its reset.
4. Press the Station 1 button; the three console buttons are now active. By pressing Station 1 you can
reduce the TOF while by pressing Station 2 you can increase it.
5. Insert an A4. sheet of paper into the front feed slot to check the status of the current TOF. This check
is made by printing a specific test. Ifthe current TOFvalue is too high, printing may occur off the sheet
of paper.
6. Press "Station 1" andlor "Station 2" to decrease or increase the TOF.
7. Repeate points 6 and 7 cyclically until the calibrations are complete.
8. Press "Local" twice to permanently store the TOF and to automatically move on to the next
calibration.
Y 1002504
Service Manual
4-23