Section E; Error Messages - Toyotomi FF-V30T Installation And Operation Instructions Manual

Vented heating system
Hide thumbs Also See for FF-V30T:
Table of Contents

Advertisement

SECTION E:

ERROR MESSAGE
ERROR CODE
E-0
E-2
E-6
E-8
E-12
E-13
E-22
-- : --
Hi
Lo
11
INFORMATION
Power interrupted.
Ignition safety feature is activated.
Extinguished during operation.
Blower motor malfunction.
Overheating safety feature is activated.
Burner thermistor malfunction
Excess fuel in the burner
Ignition failure three times
No fuel.
Timer is not setting.
Room temperature is higher than 35˚C.
Position of room temperature sensor is not correct.
Room temperature is lower than -10˚C.
Room thermistor malfunction or disconnected.
WHAT TO DO
Re-ignite the heater
Contact your dealer
Contact your dealer
Contact your dealer
Clean the air filter and remove dust.
Contact your dealer
Contact your dealer
Contact your dealer
Refill removable tank.
Set the timer.
Check the position of room temperature
sensor.
Check the position of room temperature
sensor.