Marquis Spas Owner's Manual page 6

Hide thumbs Also See for Marquis Spas:
Table of Contents

Advertisement

qualify for labor coverage. These parts can be purchased or exchanged under
warranty at your authorized Marquis Spas
CONSTANTCLEAN™ WATER MANAGEMENT WITH BUILT-IN SANITATION
SYSTEM (OPTION)
Not available in all international markets. (See Built-in Sanitation System)
Factory Default Settings:
• Filter Cycle Duration: F1 (45 minutes)
• Filter Cycles: 2C (twice per day)
• Smart Logic: 1H (1 hour)
OZONATOR (OPTION)
The ozone generator functions whenever the system is running on filter or clean
up cycles.
CAUTION: Do not block ozone injector fitting (see spa diagrams). Blockage or
partial blockage could result in back pressure that could flood the ozonator and
result in failure.
SMARTCLEAN™ FILTRATION
Your spa is preset at the factory with a default setting to filter itself using the jet
pump on low-speed for 45 minutes two times per day. These settings represent
the filter settings necessary for average use. The timing of the first filter cycle is
determined by when the spa was initially energized. The first cycle begins six
minutes after this initial power-up. The second filter cycle begins 12 hours after
the first cycle.
To adjust the filter settings
Press the SETTING pad to display the filter time settings (F1, F2, F4, F6). Use
the TEMP+- pad to scroll through the options. When desired selection has been
reached, press the SETTING pad again to enter selection and advance to the
filter cycle settings (2C, 1d, 1n). For example, if you select 2C and F2, your spa
will filter two hours twice a day for a total of four hours of filtration daily.
Use the TEMP+- pad to scroll through filter cycle options. When desired
selection has been reached, press the SETTING pad to enter selection and
advance to the smart logic settings.
Selectable filter cycles and cycle duration
• 2C: twice per day (once every 12 hours)
• 1d: once during the day
• 1n: once during the night
• F1: 45 minutes
• F2: 2 hours
• F4: 4 hours
• F6: 6 hours
SMARTCLEAN™
Your spa is preset at the factory with a default setting to filter for one hour (1H)
every time your spa is used. This SmartClean™ cycle begins 30 minutes after
the spa light or jet pump has been deactivated. The pump runs on low-speed to
filter the water for the cycle's duration.
Selectable SmartClean Settings
• 1H: 1 hour
• 2H: 2 hours
• 3H: 3 hours
• 4H: 4 hours
• OH: Off
To adjust the SmartClean settings:
Use the TEMP+- pad to scroll through options. When desired selection has been
reached press SETTING pad to enter selection and exit settings mode.
TEMPERATURE DISPLAY AND ADJUSTMENT
Factory Default Settings:
• Temperature: 37°C
dealer.
®
®
M A R Q U I S
S P A S
The LCD window displays the actual water temperature. Pressing the TEMP+-
pad makes the numbers flash, then pressing the pad again (repeatedly)
increases the set temperature one degree at a time, up to 40°C. After a short
pause, the actual temperature displays. Press TEMP+- pad repeatedly to
decrease the set temperature to 27°C.
HEAT LIGHT
The HEAT light illuminates when the heater is on. The pump circulates on low-
speed whenever the thermostat calls for heat.
HEAT MODE
Your spa comes preset in the standard heat mode. The heat mode can be
adjusted to one of three different settings:
Standard Mode (St)
The spa water heats to the temperature as set at the bather's panel. In this
mode, the filtration pump turns on for two minutes every half-hour to "poll" or
check the water. If heat is needed, the unit heats to the set temperature. The
LCD window steadily displays the actual temperature in this mode.
Economy Mode (Ec)
In this mode, the spa only heats to the set temperature during a filter cycle. The
LCD window displays "Ec" alternately flashing with the actual temperature when
the spa is up to temperature and "Ec" steadily when the water temperature is
below the set temperature.
Sleep Mode (SL)
Your spa will maintain a water temperature that is 7°C below the set
temperature. The heater functions only during a filter cycle. The LCD window
displays "SL" flashing alternately with the actual temperature when the spa is up
to set temperature and displays "SL" steadily when below set temperature.
To Adjust the Heat Mode:
First press the SETTING pad to display the heat mode settings (St, Ec, SL). Use
the TEMP+- pad to scroll through the options. When desired selection has been
reached, press SETTING pad again to enter selection and advance to the filter
cycle settings (F1, F2, F4, F6).
Maintenance Reminders
• CL: Clean Filter LED will illuminate every 30 days.
• CH: Change Water LED will illuminate every 90 days.
To reset maintenance reminders, press SETTINGS pad.
SYSTEM LOCK
Once you find and establish the settings that work best for your individual needs,
use system lock to keep from inadvertently changing the settings.
Press the TEMP+- pad and then immediately press the SETTING pad. Unlock
by repeating sequence. While the system is locked, you may still operate the
jets and light. The LCD window displays LC to indicate the system is locked
when you try to change the temperature or settings.
REMOTE CONTROLS
(See SPA OPERATION, Jets)
SPA CONTROL OPERATION
Epic
Show
O W N E R ' S
M A N U A L
39˚ C
6

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents