  • Page 1 ® Ve c to r21 Sw i m S pa s 2 0 2 3 Ow ne r’ s M anual...
  • Page 2 OWNE R’S MANUAL WELCOME TO THE ULTIMATE SWIM SPA EXPERIENCE! We sincerely hope your spa life is a pleasant experience. If problems should arise, contact your authorized Marquis dealer. Or contact Marquis at any of ® the following: Email: serviceone@marquiscorp.com Web: www.MarquisSpas.com...
  • Page 3: Table Of Contents

    VECTOR21 OWNE R’S MANUAL I NDE X • IMPORTANT SAFETY INSTRUCTIONS 240V, Permanently Installed Models ..............3-7 Personal Safety ......................7 • INSTALLATION INSTRUCTIONS Location ........................8-9 Filter Cartridges ....................... 10 Electrical Requirements ..................11-12 • STARTING YOUR SWIM SPA................13-14 •...
  • Page 4: Important Safety Instructions

    SAFE TY I NS TRUCTIONS The following instructions contain important safety information. We strong- ly encourage you to read and apply them. IMPORTANT SAFETY INSTRUCTIONS WHEN INSTALLING AND USING THIS ELECTRICAL EQUIP- MENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING: READ AND FOLLOW ALL INSTRUCTIONS 2.
  • Page 5 S AFE TY INS TRUCTIONS 240 VOLT, PERMANENTLY INSTALLED MODELS 4. A ground terminal is provided on the control box. To reduce the risk of electric shock, connect this terminal to the grounding terminal of your electrical service or supply panel with a continuous green, insulated cop- per wire.
  • Page 6 12. DANGER: Children are especially sensitive to hot water. At no time should children have unsupervised access to the spa. Children must not be allowed to climb onto the spa cover. All Marquis spas are equipped with a locking cover that meets the ASTM F1346-91 Standard for Safety Covers.
  • Page 7: Personal Safety

    S AFET Y INS TRUCTIONS PERSONAL SAFETY Prolonged immersion in hot water can result in HYPERTHERMIA, a dan- gerous condition which occurs when the internal temperature of the body reaches a level above normal (98.6°F, 37°C). The symptoms of hypertherm- ia include dizziness, fainting, drowsiness, lethargy, and a body temperature above 98.6°F (37°C).
  • Page 8 S AFE TY INS TRUCTIONS Other booklets about spa safety are: “Children Aren’t Waterproof,” “Pool and Spa Emergency Procedures For Infants and Children,” “Layers of Pro- tection” and “The Sensible Way to Enjoy Your Spa” published by Association of Pool & Spa Professionals. WARNING: The use of alcohol, drugs, or medication can greatly increase the risk of fatal hyperthermia in swim spas and spas.
  • Page 9: Installation Instructions

    INSTALLATION INS TRUCTIONS LOCATION For your vessel to function properly and safely, it must be located on a hard, flat, stable, and level surface on a 6” to 8” (152mm to 203mm) thick concrete pad that can support 200lbs. per square inch. Inground vessels require special installation techniques and should be planned in conjunc- tion with your authorized dealer.
  • Page 10 OUT DOOR & PATIO INSTALLAT ION OUTDOOR INSTALLATION To install the vessel outdoors, a flat level concrete reinforced pad at a mini- mum thickness of 6” - 8” or 152mm - 203mm is required. Placement of the vessel on pavers, gravel, or dirt is not approved and will void the warranty.
  • Page 11: Filter Cartridges

    INSTALLATION INS TRUCTIONS SHUT-OFF VALVES Your spa is equipped with shut-off valves (see EQUIP- MENT DIAGRAM) that shut off the water flow to the equipment system for authorized Marquis Dealer ® service. At times, a new spa or one that has recently...
  • Page 12: Electrical Requirements

    INSTALLATION INS TRUCTIONS SUCTION GUARDS The suction guard(s) in the footwell of your spa is an opening through which the jet pump(s) draws water. The suction fittings have an integrated vacuum release built into them. In the event that a suction fitting gets blocked, air will be induced causing the pump to cavitate and the water flow interrupted.
  • Page 13 INSTALLATION INS TRUCTIONS • Permanently connected (Hard wired). • Rated 240V, 60Hz, 50A, three wires (#6 copper) plus ground (#8 copper (8.42mm )), [4 wires total]. • Circuit breaker or fuse size: 50A. • A disconnecting means must be installed within sight from the equipment and at least 5 feet (1.52m) from the inside walls of the spa.
  • Page 14 S TARTING Y OUR S P A THERAPY PUMP(S) Startup procedure for all models 1. Place spa on a hard, flat, level surface. Make sure the power supply is off. 2. Make sure the suction guard(s) in the footwell are in place and undamaged.
  • Page 15 Fading, staining, torn stitching of the spa cover and broken foam cores are not covered under the warranty for any reason. Spa covers do not qualify for labor coverage under the warranty. These parts can be purchased or exchanged under warranty at your authorized Marquis Dealer. ®...
  • Page 16 2022 V150P Components THE V150P 1-6-22 RED HANDLE Reference # Fitting Description Qty Holesaw size Component Identification Qty. Ozone Wall Fitting 1 1/4" Ozone fittings Frog Wall Fitting (OPTIONAL) 1 1/4" 200 series Vector Jet 1 1/2" Spa Frog wall fitting (optional) straight Directional Jetpod cone...
  • Page 17 THE V150P ZONES ZONE 1A ZONE 1B ZONE 1C ZONE 1D ZONE 1E ZONE 1F ZONE 1G ZONE 2...
  • Page 18 2022 V150W Components 1-6-22 THE V150W Component Identification Qty. Reference # Fitting Description Qty Holesaw size Ozone fittings Ozone Wall Fitting 1 1/4" Spa Frog wall fitting (optional) Frog Wall Fitting (OPTIONAL) 1 1/4" Directional Jetpod 200 series Vector Jet 1 1/2"...
  • Page 19 THE V150W ZONES ZONE 1A ZONE 1B ZONE 2...
  • Page 20 THE V174S Component Identification Qty. Ozone fittings Spa Frog wall fitting (optional) Directional Jetpod Directional Jetpod Conal Jetpod Orbital Jetpod Directional Jetpod Orbital Jetpod Whitewater-4 jet Pop up water feature Suction fitting Floor drain control valve Neck Jet valve Air control valve Waterfall valve LED lights Starlights™...
  • Page 21 THE V174S ZONES Pump 2 Pump 1 - A Pump 3 Pump 1 - B Pump 1 - Neck Jets...
  • Page 22 THE V174K Component Identification Qty. Ozone fittings Spa Frog wall fitting (optional) Directional Jetpod Directional Jetpod Conal Jetpod Orbital Jetpod Directional Jetpod Orbital Jetpod Whitewater-4 jet Pop up water feature Suction fitting Floor drain control valve Neck Jet valve Air control valve Waterfall valve LED lights Starlights™...
  • Page 23 THE V174K ZONES Pump 2 Pump 1 - A Pump 3 Pump 1 - B Pump 1 - Neck Jets...
  • Page 24: Vector21 Swim Spa Control Operation

    VECTOR21 SPA CONTROL OPERATION START-UP FILLING THE SWIM SPA The water level should be filled to two-thirds up the skimmer fins. Fill only with clean water. If your water source contains particles, please contact your dealer for a fill filter.
  • Page 25 VECTOR21 SPA CONTROL OPERATION Adjusting temperature (factory default 100° F) To adjust the temperature of the water, press the TEMP +/ – button. The first press of the button will display the set temperature and begin to flash. Continue to press or hold the TEMP +/ – to reach the desired set temperature.
  • Page 26 VECTOR21 SPA CONTROL OPERATION for normal use and operation. To access any of the following features press TEMP +/- and then Light: then scroll through the features by continuing to press the LIGHT button. You exit the programming mode at any time by continuing to press the LIGHT button until you arrive back at the temperature display or by simply pausing for 30 seconds.
  • Page 27 VECTOR21 SPA CONTROL OPERATION V150 COSMIC AUDIO SYSTEM (Optional) Please refer to the manufacturer’s owner’s manual for features, operation, and troubleshooting. This system will support bluetooth connectivity to your hand-held devise. NOTE: Avoid water splashing on the stereo face. Never operate the stereo with wet hands.
  • Page 28: V174S & V174K

    SWIM SPA CONTROLS: V174S & V174K MAIN TOUCH SCREEN ICONS A. Display off button: Touch this to turn off the display at any time. B. Heat Mode: R = Ready IR = Rest C. Ozone: If O3 is being displayed, ozone is on. If it is not being displayed, it is off. D.
  • Page 29: V174S & V174K

    SWIM SPA CONTROLS: V174S & V174K SETTING THE TIME OF DAY To access the screen to set the time of day, please follow these steps. Note: If you need to go back to a previous screen, touch the back arrow. 1.
  • Page 30 SWIM SPA CONTROLS: V174S & V174K SET THE TEMPERATURE In this example we will set the Set Temperature to 102°F (39°C). • Press the water temperature display button (A) to make the temperature menu appear (B). The center box with the arrow (C) indicates the current Set Temperature.
  • Page 31 SWIM SPA CONTROLS: V174S & V174K SETTING FILTRATION CYCLES Should you want to change your factory default filtration settings, see the instructions below. The factory default settings are for two filtration cycles per day for 1.0 hour per cycle. The first cycle with start at 8:00 PM and the second cycle will start at 8:00 AM.
  • Page 32 SWIM SPA CONTROLS: V174S & V174K SETTING THE UNITS Features found in the Units screen allow for changing how the temperature scale and time are displayed on the home screen. To access the screen to make these changes, please follow these instructions On the home screen, touch the Settings icon located on the bottom of the display...
  • Page 33 SWIM SPA CONTROLS: V174S & V174K TURNING ON REMINDERS Reminders can be helpful to automatically notify you when general maintenance items needs to be checked. Because usage patterns can vary widely from one owner to another, the reminders are turned off by default. Below is a list of reminders that will become active if turned on. •...
  • Page 34 SWIM SPA CONTROLS: V174S & V174K SETTING THE LANGUAGE The control panel is able to display the following languages • English (Factory Default) • Spanish • German • French • Swedish To access the screen to make any changes, please follow these instructions.
  • Page 35 SWIM SPA CONTROLS: V174S & V174K SETTING THE PANEL DISPLAY You can make changes to how long the panel stays illuminated as well as altering the user control sequence for waking the panel up. To access the screen to make any changes, please follow these instructions.
  • Page 36 SWIM SPA CONTROLS: V174S & V174K VIEWING DIAGNOSTICS This feature can be useful when reviewing system information or any fault codes or occurrences that may have happened during operation. Addtionally you can run periodic GFCI tests to ensure the electrical supply system is operating properly. To access this feature, please follow these instructions.
  • Page 37 SWIM SPA CONTROLS: V174S & V174K Jets 2: Controls bank of three jets on the swim end.Touch- ing this button once will turn on to low speed. You will know it is on when a white ring around the button is present. Touching the button a second time will turn the pump on to high speed.
  • Page 38 SWIM SPA CONTROLS: V174S & V174K BLUETOOTH AUDIO (OPTIONAL) spaTouch A - Play/Pause B- Bluetooth Screen C - Song Title, Artist D - Settings E- Volume Up/Down F - Mute Control G- Invert Display H- Remaining Time I - Track Next/Previous J- Progress Bar K - Elapsed Time L - Back...
  • Page 39 SWIM SPA CONTROLS: V174S & V174K PAIR SMART DEVICE Follow these steps to pair your smart device with the bbaTM3 amplifier (E). Power up the spa. IMPORTANT: All paired devices are erased from the bbaTM3 amplifier when power to the spa is cycled. While the bbaTM3 amplifier forgets your smart device when the spa power is cycled, your smart device might not forget the bbaTM3 amplifier.
  • Page 40 SWIM SPA CONTROLS: V174S & V174K spaTouch ADJUST AUDIO SETTINGS Follow these steps to adjust the audio settings. Navigate to the Bluetooth screen (A); refer to page Press the Settings button (B) to enter the Settings screen. Make desired changes to the audio settings. There are two types of filters: Low Pass and High Pass.
  • Page 41 SWIM SPA CONTROLS: V174S & V174K MESSAGE BUTTONS Message buttons provide reminders to help you keep your spa running smoothly. Message buttons also provide warning information that helps spa technicians with troubleshooting. When a message button appears (C), press it to view the corresponding message (D) or (G).
  • Page 42 SWIM SPA CONTROLS: V174S & V174K HEATER-RELATED MESSAGES The water flow is low – M016** There may not be enough water flow through the heater to carry the heat away from the heating element. Heater start up will begin again after about 1 minute. See “Flow Related Checks” below. The water flow has failed* –...
  • Page 43 SWIM SPA CONTROLS: V174S & V174K SYSTEM-RELATED MESSAGES Program memory failure* – M022** At Power-Up, the system has failed the Program Checksum Test. This indicates a problem with the firmware (operation program) and requires a service call. The settings have been reset. (Persistent Memory Error)* –...
  • Page 44 SWIM SPA CONTROLS: V174S & V174K Change the water May appear on a regular schedule, i.e. every 90 days. Change the water in the spa on regular ba- sis to maintain proper chemical balance and sanitary conditions. You may want to set a reminder to purge, drain and fill your swim spa every 90 days to avoid total dissolved solids buildup in your water which can render your sanitizer ineffective.
  • Page 45 VECTOR21 TROUBLESHOOTING GUIDE PLEASE NOTE: The following corrective actions may be performed by the spa owner. If the trouble cannot be corrected in the steps below, please contact your authorized dealer for service. (Improper servicing by an unau- thorized service provider or spa owner could result in damage not covered by the warranty and could cause serious injury.)
  • Page 46 VECTOR21 TROUBLESHOOTING GUIDE HTR MAY BE DRY: There is little to no water flow through the heater. Check that the slice valves are fully open. Contact dealer for service. HTR TOO HOT: One of the sensors has reached 118°F (48°C). Do not enter the water.
  • Page 47 VECTOR21 EQUIPMENT DIAGRAMS MODEL V150P 2023 V150P EQUIPMENT (US, CA, INT) 6-21-23 DEL OZONE SPA 1 or 2 4 or 5 6 or 7 Reference # Fitting Description MQBP20 (60Hz) Equipment System (US CA) MQBP21 (50Hz) Equipment System (INT) MODEL V150W...
  • Page 48 VECTOR21 EQUIPMENT DIAGRAMS MODEL V174S DEL OZONE SPA 1 or 2 4 or 5 6 or 7 6 or 7 Component Qty. Control box and heater Ozonator (optional) 2-speed pump 2-speed pump 2” Slice valves Hose bib drain Audio system (optional) Starlights™...
  • Page 49 VECTOR21 S PA MAI NTE NANCE HOW TO PROLONG THE LIFE OF YOUR SWIM SPA There are some simple steps you can take to prolong the life of your hot tub. Please follow the guidelines listed below to ensure the most trouble- free and enjoyable use of your spa.
  • Page 50: Maintenance

    CAUTION: Overtightening of the filter can cause the filter or filter housing to crack. Tighten filter until it is snug. NOTE: Filters and filter lids do not qualify for labor coverage. These parts may be purchased or exchanged under warranty at your authorized Marquis Dealer. ®...
  • Page 51 VECTOR21 MAINTENANC E EVERY THREE TO FOUR MONTHS Draining and Filling the Vessel The average vessel needs to be drained every three to four months. After months of continually adding chemicals to the water and introducing body oils and lotions, the water can be difficult to manage and chemicals are not as effective as usual.
  • Page 52 AS NEEDED MAINTENANCE Cover Care It is recommended that you use Marquis Cover Cleaner to keep the Dura- Cover clean and conditioned. Proper care of the cover increases the life ®...
  • Page 53 VECTOR21 MAINTENANC E Water Line To avoid buildup of oils and lotions at the water line, clean the interior weekly or when needed. We suggest the Glove Sponge to clean without scratching. NOTE: Do not use the same brush or sponge to clean the exterior of the spa and the interior of the spa.
  • Page 54 VECTOR21 SPA CARE GUIDE IMPORTANT CHEMICAL SAFETY PROCEDURES Always keep chemicals out of reach of children. Read product labels carefully prior to use. When dissolving, always add chemicals to water, do not add water to chemicals. Some dry chemicals should be dissolved prior to adding them to the vessel.
  • Page 55 VECTOR21 SPA CARE GUIDE WATER CARE There are three things necessary for clean, safe water: 1. CIRCULATE: Water has to be circulated regularly; it can not be stagnant. 2. FILTER: Water has to be filtered to remove particulates and debris.
  • Page 56 VECTOR21 SPA CARE GUIDE Calcium Hardness Do not use soft water in your spa. It is critical to have calcium in your water. The ideal range of calcium is between 150 – 250 ppm. The calcium hard- ness is normally adjusted when filling or refilling after draining the spa. High calcium levels can cause scale buildup on spa surfaces and equipment.
  • Page 57 VECTOR21 SPA CARE GUIDE Total Alkalinity Alkalinity acts as a buffer to prevent the pH from changing as other sub- stances are added to the water. Stability of the pH is directly related to the alkalinity. The alkalinity should be between 80 - 140 ppm. Alkalinity below 80 ppm makes it difficult to stabilize the pH.
  • Page 58 SPA CARE & E NJOY MENT GUIDE SHOCK Initial Treatment Shock the vessel using granular Chlorine Sanitizer Spa Shock. Add directly to the vessel per the instructions on the container. For the initial treatment, Chlorine Sanitizer is preferred as it will also establish a residual of sanitizer.
  • Page 59 SPA CARE & E NJOY MENT GUIDE AS NEEDED PRODUCTS pH Increaser Alkalinity Increaser pH & Alkalinity Decreaser These three products work to raise or lower the pH and alkalinity in the vessel. They are only needed if the test strip indicates the levels are not in the ideal ranges.
  • Page 60 SPA CARE & E NJOY MENT GUIDE Foaming P: High concentration of body oils, lotions or soaps, as well as excessive or- ganics. S: Use Defoamer and adjust pH and sanitizer as needed. P: Excessive foaming past 24 hours. S: Check and balance calcium levels, excessive foaming can be an imbalance of calcium.
  • Page 61 SPA CARE & E NJOY ME NT GUIDE STEP INSTALLATION (OPTION) The step and mounting brackets may be placed along a straight side of the spa, most often centered to the entry location. Find the center of the spa side where you want to mount the step.
  • Page 62: Warranty

    WHAT MARQUIS CORP. WILL DO IN THE EVENT OF A PROBLEM Marquis Corp. agrees to repair any plumbing or surface defects and to repair or furnish a replacement for any factory-installed component covered under this warranty which, upon test and examination by Marquis Corp., proves to have...
  • Page 63 VECTOR21 LIMITED WARRANTY In the event that Marquis Corp. or its agent determines that your problem can be ad- dressed by providing a replacement part to you for installation in your spa, a replace- ment part will be provided to you at no charge when you return the defective part. All...
  • Page 64 The stereo system Limited Warranty is made only to the original purchaser of the spa and is not transferable. In no event shall any obligation of Marquis Corp. extend beyond the original period of any applicable warranty determined according to the effective warranty date of the original purchaser.
  • Page 65 DISCLAIMERS There are no additional warranties, express or implied, which extend beyond the terms of this limited warranty. Marquis Corp. makes no warranty of merchantability of the goods or the fitness of the goods for a particular purpose. No other person or entity has been authorized to make any warranty, representation or promise of performance not included in this express written warranty, and Marquis Corp.
  • Page 66 MA R Q U I S CO R P 59 6 H O F F M AN R O AD Marquis is a registered trademark of Marquis Corp. Marquis reserves the rights to make product modi- I NDEP EN DEN CE, O R 9 73 5 1 fications and enhancements.

This manual is also suitable for: