Asko DW90 Series Service Manual page 21

Dishwasher
Table of Contents

Advertisement

Service manual DW90
Programs and control unit
Program flow description
Presented below is the Quick program, no options selected (DW90.1).
Step
Component
Main wash
1
Drain process
2
Inlet process
3
Circ. pump
4
Pause
5
Circ. pump
6
Pause
If ECO is
Circ.pump
set
Drain process
Inlet process
7
Circ. pump + Combi dispenser
8
Circ. pump + Element
9
Circ. pump
10
Cleaning cycle for container
11
Drain process
1:st rinse
12
Inlet process
13
Circ. pump
14
Pause
15
Circ. pump
16
Drain process
2:nd rinse
17
Inlet process
18
Circ. pump
19
Cleaning cycle for container
20
Drain process
3:rd rinse
21
Inlet process
22
Circ. pump
23
Circ. pump + Element
24
Circ. pump + Combi dispenser
25
Drain process
Drying
26
Fan
27
Signal
Explanations
Cleaning
Cleaning cycle for container
process
*
Inlet
Inlet process
process
**
Drain
Drain process
process
***
Time
Comment
6 sec 12-16 sec when restarting or if an earlier program was interrupted
255 sec Maximum time. Inlet time is controlled by a flow meter**
3 sec
30 sec If water temperature is >30°C ECO program starts (DW90.1)
30 sec
5 sec
120 sec
120 sec Maximum time. Time is controlled by level sensor***
255 sec Maximum time. Inlet time is controlled by a flow meter**
10 sec
60°C If ECO 30°C
30 sec
90 sec Maximum time 90 sec. Minimum time 76 sec*
120 sec Maximum time. Time is controlled by level sensor***
255 sec Maximum time. Inlet time is controlled by a flow meter**
3 sec
5 sec
3 sec
120 sec Maximum time. Time is controlled by level sensor***
255 sec Maximum time. Inlet time is controlled by a flow meter**
150 sec
90 sec Maximum time 90 sec. Minimum time 76 sec*
120 sec Maximum time. Time is controlled by level sensor***
255 sec Maximum time. Inlet time is controlled by a flow meter**
60 sec
60°C
10 sec Pulses (varies depending on the setting of rinse aid)
120 sec Maximum time. Time is controlled by level sensor***
480 sec
4 sec If signal is selected
90 sec The circ. pump stops and the drain pump runs for 2 sec. The circ.
pump runs for 3 sec. and then rests for 5 sec. In total this is repeated
eight times, but the fifth time the circ. pump is resting for 8 sec instead
of 5 sec, when spray arm diverter is switching to the upper spray arm.
255 sec A flow meter signals the flow in pulses. The control unit (CU)
determines how many pulses to be calculated for each inlet. If not 80
pulses has been reached within 60 sec or a specific number of pulses
is not reached within 255 sec, the program will be interrupted.
120 sec The drain pump starts and pumps out until the level sensor reaches
a specified value. After that, the drain pump continues for additional
10 sec. The total time depends on how long it takes to reach the
specified value from the level sensor. If the specified value is not
reached within 120 sec, the program will be interrupted.
21