2.
The appliance must be isolated from the gas
supply piping system by closing its individual
manual shutoff valve during any pressure
testing of the gas supply piping system at test
pressures equal to or less than 1/2 psi
(3.45 kPa).
NOTE: Line pressure must be kept below 10" (Nat),
13" (LP) during leak test to avoid damage to the gas
valve.
The required gas pressure for proper operation of each
Miraclean Griddle® is 4" water column for natural gas
and 10" water column for propane gas at the manifold.
If more than one gas unit is on the same supply line,
you may require a larger line. Consult your local gas
company to assure adequate volume and pressure.
Refer to serial plate for proper gas requirement for
your particular model.
FLEXIBLE GAS CONNECTORS
AND QUICK DISCONNECT DEVICES
For an appliance equipped with casters:
The installation shall be made with a connector that
complies with the Standard for Connectors for Movable
Gas Appliances, ANSI Z21.69 or the Standard for
Connectors for Moveable Gas Appliances, CAN/CGA-
6.16, and a quick disconnect device that complies
with the Standard for Quick-Disconnect Devices for
Use With Gas Fuel, ANSI Z21.41 or the Standard
for Quick Disconnect Devices for Use with Gas Fuel,
CAN1-6.9.

RESTRAINING DEVICES

NOTICE
Adequate means must be
provided to limit the movement of
the appliance without depending
on the connector and the quick-
disconnect device or its associated
piping to limit the appliance
movement. Griddle installation
Restraining devices
on stands with caster, casters
required.
and jam nuts must be completely
tightened.
The restraint means must be attached to the
rear of the Miraclean® Griddle within 2" of the center
line width and approximately 1-5/8" from the bottom
of the cabinet back to allow the restraining bolt to be
anchored to the cabinet back between the cabinet
bottom and inner liner to ensure positive support to
restrain Miraclean® Griddle movement and not depend
on the fl exible gas connector, quick-disconnect or pip-
ing to limit the Miraclean® Griddle movement.
If disconnection of the restraint is necessary, it must
be reconnected when the Miraclean®Griddle is re-
turned to its originally installed position.
GAS GRIDDLE - SERIES 2000

LEVELING

The Miraclean® Griddle will operate at its highest
effi ciency when properly leveled. Place a level on the
Miraclean® Griddle plate from side to side. For griddles
on legs, the bottom foot of the leg is adjustable. Turn
counter clockwise to decrease height, or clockwise to
increase height until level. For griddles on stands with
casters, the casters are adjustable by loosening the
jam nut. When the desired level is reached, tighten the
jam nut. Adjustments of more than 3/4" are not rec-
ommended on any caster. The same procedure should
be followed to level the Miraclean® Griddle from front
to back.