MILLIVOLT CONTROL VALVE
To check Resistance of the gas valve, connect one wire
to the valve as shown.
TP
TH
1. Resistance between the THTP & TH terminals must
be 11.5V±0.2V
2. Resistance between the THTP & TP terminals must
be 10.0V±0.2V
If resistance is outside of specifi cations listed, the gas
valve must be replaced.
BEFORE REPLACING THERMOPILE CHECK
MILLIVOLT READINGS
THERMOPILE READINGS
With all wires connected, with the pilot on and burners
off, the thermopile reading at the TP&THTP terminals
should be ~325mv. With the burners on, the millivolt
reading should be ~200mv.
WARNING AND OPERATING PLATES
All warning and operating plates on the Keating Mira-
clean® Griddle should be in place at all times. If plates
are damaged or lost, replace them immediately.
|