12
PROGRAM FUNCTION (Programmable 7 day thermostat)
The program function operates as follows:
4
Each day has two periods (P1 , P2). Each period
has an "ON" time and an "OFF" time.
5
Each period is programmed for weekdays (Monday
through Friday) and weekends (Saturday and
Sunday).
6
Each period has a set temperature.
The remote comes pre-programmed for the following:
1
Monday through Friday P1 ON @ 6:00AM OFF @ 8:00AM 70°F.
2
Monday through Friday P2 ON @ 6:00PM OFF @ 9:00PM 70°F.
3
Saturday and Sunday P1 8:00AM to 10:00AM 70°F.
4
Saturday and Sunday P2 7:00AM to 10:00PM 70°F.
To adjust the program times and temperatures, do the following:
A
Press the Function ("Fn") Key until the program functions start to blink.
B
Press the "Set" button for 5 seconds.
C
The P1 "ON" time will blink. Use the arrows to select the desired time.
D
Press the "Set" button. This sets the P1 "ON" time.
E
The temperature will blink. Use the arrows to select the desired temperature.
F
Press the "Set" button. This sets the temperature for P1.
G The P1 "OFF" time will blink. Use the arrows to select the desired time.
H
Press the "Set" button. This sets the P1 "OFF" time.
I
REPEAT STEPS "C" through "H" for P2.
J
REPEAT STEPS "C" through "H" for the weekend P1 and P2.
NOTE: P2 must start after 4:00PM.
To Turn PROGRAM FUNCTION ON
A
Press the Function ("Fn") Key until the program functions start to blink.
B
Press the "Set" button. The You will notice the P1 or P2 symbol will appear in the program
section of the remote next to the time. This indicates the remote is in PROGRAM
FUNCTION (Programmable thermostat).
To Turn PROGRAM FUNCTION OFF
A
Press the Function ("Fn") Key to select either manual or thermostat mode.