16.3 PTP 58500 Reference Information

This section contains reference information that is specific to the PTP 58500 frequency
variant.

16.3.1 PTP 58500 Examples of Regulatory Limits

Table 41 shows how the regulatory limits currently apply in specific countries. Operators
should note that regulations are subject to change.
Table 41 – PTP 58500 Examples of Regulatory Limits
Examples of Regulatory Limits
Equipment can be operated in any mode, best results will be obtained using
USA/ Canada/
Region 1 settings. There are some limitations on the use of antennas above 4ft
Taiwan
diameter plus a 1 dB band edge power reduction.
Under UK Regulations, operation of this product is allowed with a License Key
for Region 4 . This implements Radar Detection with barring of the band from
5795 MHz to 5815 MHz and above 5850 MHz. It limits the EIRP to the
UK
Regulatory Limits below:
EIRP ≤ Max of [(23 +10 x Log(Channel BW)) and 36] dBm
Under Eire Regulations, operation of this product is only allowed with a License
Key for Region 6. This limits the EIRP to the Regulatory Limits below:
Eire
EIRP ≤ Max of [(20 +10 x Log(Channel BW)) and 33] dBm
Norway
Under Norway Regulations, operation of this product is only allowed with a
License Key for Region 7. This implements Radar Detection and limits the
EIRP to the Regulatory Limits below:
EIRP ≤ Max of [(40 +10 x Log(Channel BW)) and 53] dBm
Germany
Operation of this product is only allowed with a License Key for Region 22. This
limits the band of operation to 5755 MHz to 5875 MHz and limits the EIRP to
the Regulatory Limits below:
EIRP ≤ Max of [(23 +10 x Log(Channel BW)) and 36] dBm
Denmark
Operation of this product is only allowed with a License Key for Region 27.
This implements Radar Detection with barring of the band from 5795 MHz to
5815 MHz. It limits the EIRP to the Regulatory Limits below:
EIRP ≤ Max of [(23 +10 x Log(Channel BW)) and 36] dBm