Cable measuring card: A cable measuring card must NEVER be used at the ODU end
connected to power from the PIDU Plus. It must only be used at the bottom of the mast with
a multimeter. This is because the PIDU Plus voltage exceeds the limit allowed in some
countries for safe handling in wet conditions and therefore may create a safety hazard.
Alternative DC supplies: When using alternative DC supplies (via the PIDU Plus DC in
terminals
as
described
Configurations"), such as battery-backed DC power source, the supply MUST comply with the
following requirements:
The voltage and polarity is correct and is applied to the correct terminals in the PIDU Plus
The power source is rated as SELV
The power source is rated to supply at least 1A continuously
The power source cannot provide more than the Energy Hazard Limit as defined by
IEC/EN/UL6090, Clause 2.5, Limited Power (The Energy Hazard Limit is 240VA)
Primary disconnect device: The main power supply is the primary disconnect device.
External cables: Safety will be compromised if external quality cables are not used for
connections that will be exposed to the weather.
Non-Motorola power supply: Safety will be compromised if a different power supply is used
than the one supplied by Motorola as part of the system.
in
Section
2.8
"Redundancy
6
1 About This User Guide
and
Alternative
Powering