Biasi M96.24SM/B Service Manual page 38

Wall hung, fan flue, room sealed, high efficiency gas boiler
Hide thumbs Also See for M96.24SM/B:
Table of Contents

Advertisement

19
Ignition and detection electrodes
19.1
Function
Three electrodes are fitted on the burner. Two of them
are the ignition electrodes and are fitted near the front
part of the burner. The ignition sparks take place be-
tween their metallic edges over the central ramp of the
burner during the ignition sequence.
The third electrode is the detection electrode and it de-
tects the presence of the flame.
Ignition
Female
Fig. 74
19.2
Checks
Check the position of the electrode edges
n
Warning: isolate the boiler from the mains
electricity supply before removing any
covering or component.
1
Remove all the case panels, the sealed chamber
lid and the combustion chamber lid.
2
Check for the correct distance between the me-
tallic edges of the ignition electrodes (see
Fig. 75).
Ignition
Fig. 75
36
Detection
Male
4 mm
3
Check the integrity of the detection electrode and
ensure that its metallic edge is correctly placed
over the ramp of the burner.
Check the connection wires.
n
Warning: isolate the boiler from the mains
electricity supply before removing any
covering or component.
1
Remove all the case panels, the sealed chamber
lid and the combustion chamber lid.
2
Check for the integrity of the insulation of wires
which connect the electrodes to the ignition de-
vice.
19.3
Removal
Warning: isolate the boiler from the mains
electricity supply before removing any
covering or component.
1
Remove all the case panels, the sealed chamber
lid and the combustion chamber lid.
2
Disconnect the electrode wires from the full se-
quence ignition device.
3
Remove the plate C (see Fig. 78 on page 37).
4
Remove the burner by unscrewing the four
screws placed at the right and left sides of the
burner.
Unscrew the screws A (Fig. 76) which hold the
5
electrodes to the burner.
A
Fig. 76
6
Extract the electrodes from the burner.
7
Assemble the electrodes carrying out the removal
operation in reverse order.
Refer to Fig. 74 in order to recognise the elec-
trodes and to correctly connect the wiring.
Note: the metallic edge of the detection electrode is
longer than the one of the ignition electrodes.
Warning: After cleaning or replacement as
detailed above, if it deemed necessary to
undertake a combustion analysis, refer to
the appropriate chapter Maintenance of the
installation instructions manual.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents