Nikon VAA35001 Coolpix S1 Repair Manual page 78

Coolpix s1 digital camera
Hide thumbs Also See for VAA35001 Coolpix S1:
Table of Contents

Advertisement

Item
Electric characteristics
When voltage
increases
(Alkaline battery)
Level 1
Level 2
"Half" battery mark
・ 3.8 ± 0.1V
・ 3.4 ± 0.1V
The remaining battery power when "half" mark lights:
・ 20 ± 10%
Ratio of the film counter when "half" mark displayed to the
maximum number of shots:
・ 85 ± 5% (25℃ )
・ When the voltage increases, the battery mark disappears on the
monitor LCD. Check the AC detection level by this disappear-
ance.
・ Connect the constant-voltage power supply and check the voltage
at Level 3 ("No battery capacity"). Then, turn off the power,
increase the voltage in increments of 0.1V and turn the switch
from OFF to ON. Measure the voltage under the following
conditions. (When changing the voltage, be sure to turn off the
power.)
・Level 1 : Battery mark is turned off on the monitor LCD.
・Level 2 : Battery "half" mark lights on the monitor LCD.
- R11 ・ S1 -
Criteria
VAA35001-R.3666.A
Tools
Constant voltage
power supply
Voltmeter

Advertisement

Table of Contents
loading

This manual is also suitable for:

Coolpix s1Coolpix s1 vaa35001

Table of Contents