Connector And Cable Check - Toshiba Satellite P100 Series Maintenance Manual

Hide thumbs Also See for Satellite P100 Series:
Table of Contents

Advertisement

Troubleshooting Procedures
Procedure 3

Connector and Cable Check

LCD Module is connected to system board by an LCD/FL cable. FL inverter board is also
connected to system board by an LCD/FL cable. And, fluorescent lamp is connected to FL
inverter board by HV cable. Their cables may be disconnected from system board or FL
inverter board. Disassemble the computer following the steps described in Chapter 4,
Replacement Procedures.
If the connection is loose, reconnect firmly and restart the computer. If the problem still
occurs, go to Procedure 4.
36
Satellite P100 Maintenance Manual