IBM Remote Supervisor Adapter User Manual page 34

Ibm partner pavilion network card user manual
Table of Contents

Advertisement

Table 4. Warning remote alerts
Alphanumeric
Event
pager code
10
Redundant power
supply failure
11
Single fan failure
12
Temperature irregularity Generates an alert if any monitored temperatures are outside the
13
Voltage irregularity
14 - 19
Table 5. System remote alerts
Alphanumeric
Event
pager code
20
POST timeout
21
O/S timeout
22
Test alert
23
Power off
24
Power on
25
Boot failure
26
Loader timeout
27
PFA notification
28 - 29
5. Scroll to the bottom of the page and click Save.
28
Remote Supervisor Adapter: User's Guide
Action
Generates an alert if a redundant power supply fails.
Generates an alert if one fan fails.
warning threshold values. To access these temperature threshold values,
click the temperature readings on the System Health page. Unlike the
critical temperature event, this event will not initiate a server shutdown.
Generates an alert if any monitored voltages are outside the warning
threshold values. To access these voltage range values, click the voltage
readings on the System Health page. Unlike the critical voltage event,
this event will not initiate an automatic server shutdown.
Reserved for future use.
System alerts
System alerts are generated for events that occur as a result of system
errors. If the Select all system alerts check box is selected, an alert
can be sent for any system alert.
Notes:
a. The Select all system alerts check box is not available on all
servers.
b. Hard disk drive Predictive Failure Analysis
monitored.
Action
Generates an alert if an enabled POST timeout value is exceeded. The
POST timeout value is configured in the Server Timeouts section on the
System page.
Generates an alert if an enabled operating system timeout value is
exceeded. The operating system timeout value is configured in the
Server Timeouts section on the System page. The O/S timeout alert
must be checked to enable remote blue screen capture.
Generates an alert if the Generate Test Alert button is clicked on the
Remote Alert Recipients page.
Generates an alert if the server is turned off.
Generates an alert if the server is turned on.
Generates an alert if an error occurs that prevents the server from
starting.
Generates an alert if an enabled server loader timeout value is
exceeded. The system loader timeout value is configured in the Server
Timeouts section on the System page.
Generates an alert if a PFA notification is generated by the server
hardware. This feature is available only on server that have PFA-enabled
hardware.
Reserved for future use.
®
(PFA) alerts are not

Advertisement

Table of Contents
loading

Table of Contents