Level M3: Error Log - Gaggia PLATINUM VOGUE Technical & Service Manual

Table of Contents

Advertisement

Level M3 : Error Log
3.1 Errors List
The following are shown at this level:
-)
The last 20 errors involving the CA
-)
The date the error occurred.
The error map is shown below:
Code
Brief description
Coffee grinder blocked.
01
TORQUE_FAULT_FWD
TIMEOUT_FWD
03
TIMEOUT_FWD_DOWN
HOME_WHILE_WORKING
TORQUE_FAULT_RWD
04
TIMEOUT_RWD
WORK_WHILE_HOMING
HOME_AND_WORK_PRESSED
16
Water circuit blocked.
05
SENSOR1_SHORT
10
11
SENSOR1_OPEN
14
TEMPERATURE_BO_TOO_HIGH
TEMPERATURE_BO_OUT_CONTROL
15
No zero crossing.
19
3.2 Clear all?
pressing YES will delete all errors at level 3.1.
TALEA Section 05
REV00 - August 06
Ideas with Passion
Description
COFFEE GRINDER ERRORS
The coffee grinder won't turn: there may be something obstructing
the grinders or beverage signal has not been read correctly by the Hall
probe in the coffee grinder.
BREW GROUP ERRORS
Maximum force exceeded in forward movement to dispense position
(second attempt).
Maximum time exceeded to reach dispense position.
Maximum time exceeded to clear home position microswitch.
Home position microswitch activated while moving to work position.
Maximum force exceeded returning to home position.
Maximum time exceeded returning to rest position.
Work position microswitch activated while moving to home position.
Both the work and home microswitches are activated at the same time.
WATER CIRCUIT ERRORS
This can happen for a variety of reasons ...(trips when water not flow-
ing in turbine).
TEMPERATURE CONTROL ERRORS
Coffee heater sensor shorted.
Coffee heater sensor in open circuit.
Coffee heater temperature too high.
Coffee heater temperature out of control (not responding to stimuli:
e.g. heater on but temperature not rising).
GENERAL ERRORS
No zero crossing on card, could be caused by power card.
14/17