- Milk island present indicates the state of the milk island present microswitch.
- Caraffe present indicates the state of the milk carafe present microswitch.
- Pressing "valve" once will excite the solenoid valve.
- Pressing "water pump" once will start the pump.
- Pressing "valve" once will activate the solenoid valve.
Level T4 – Grinder unit
At this level, you can test coffee grinder function.
t.4 - Grinder unit
Next
pulses_counter
= 0
delay_time (msec)
= 0
bean_door
= ON
bean_alarm
= OFF
*
grinder
bean
test
Level T5 – Cup lift
At this level, you can check cup-lift function.
t.5 - Cup lift
Next
upper_switch
= OFF
lower_switch
= OFF
key_up
= OFF
key_down
= OFF
cup_lift
cup_lift
*
up
down
Level T6 – Grinder dose
At this level, you can test and modify the amount of coffee that is ground.
t.6 - Grinder dose
Next
Mild dose
= 63
Medium dose
= 70
Strong dose
= 77
Mild
Medium
Strong
Value
Value
Value
up
down
test
TALEA Section 05
REV00 - August 06
Ideas with Passion
- pulse_counter - indicates the number of grinding pulses the grinder performs.
- delay_time (msec) - indicates revolutions per second of the hall sensor in the coffee
grinder.
- bean_door - indicates the state of the coffee bean container lid magnetic sensor.
- bean_alarm - indicates the no coffee beans left alarm during last grinding.
- Holding and pressing "grinder" starts the coffee grinder for at least 200 grinding pulses.
- Pressing "bean test" once starts the coffee grinder to check the no coffee bean alarm.
- upper_switch - indicates the state of the moving tray up position microswitch in the up
position of the moving tray.
- upper_switch - indicates the state of the moving tray lower position microswitch in the
lower position of the moving tray.
- key_up - indicates the state of the capacitive sensor that raises the moving tray.
- key_up - indicates the state of the capacitive sensor that lowers the moving tray.
- Holding and pressing "cup_lift" moves the cup lift up to the uppermost position.
- Holding and pressing "cup_down" moves the cup lift up to the lowermost position.
- Mild dose - indicates the number of grinding pulses to set for a mild coffee.
- Medium dose - indicates the number of grinding pulses to set for a medium-strength cof-
fee.
- Strong dose - indicates the number of grinding pulses to set for a strong coffee.
- Pressing "value up" increases the number of grinding pulses for a medium-strength coffee in
steps of 5.
- Pressing "value down" reduces the number of grinding pulses for a medium-strength coffee
in steps of 5.
- "Mild" and "strong" values are equal to 10% less and 10% more respectively than the aver-
age value set.
- Pressing "value test" starts grinding at the selected strength (mild, medium or strong).
2/17