CONNECTIONS – PLUMBING
RELIEF VALVE DRAIN
DN15 copper drain lines must be fitted to the temperature pressure relief valve
and expansion control valve (if one is installed) to carry the discharge clear of
the water heater. Connect the drain lines to the valves using disconnection
unions. The drain line from the valve to the point of discharge should be as
short as possible, have a continuously downward fall all the way from the water
heater to the discharge outlet and have no tap, valves or other restrictions in
the pipe work.
A drain line from a relief valve must comply with the requirements of
AS/NZS 3500.4.
A drain line must be no longer than nine (9) metres with no more than three
bends greater than 45° before discharging at an outlet or air break. The
maximum length of nine (9) metres for a drain line is reduced by one (1) metre
for each additional bend required of greater than 45°, up to a maximum of three
additional bends. Where the distance to the point of final discharge exceeds
this length, the drain line can discharge into a tundish.
Subject to local regulatory authority approval, the drain lines from the
temperature pressure relief valve and expansion control valve from an
individual water heater may be interconnected.
The outlet of a drain line must be in such a position that flow out of the pipe can
be easily seen, but arranged so discharge will not cause injury, damage or
nuisance. The termination point of a drain line must comply with the
requirements of AS/NZS 3500.4. Drain lines must not discharge into a safe
tray.
In locations where water pipes are prone to freezing, drain lines must be
insulated, must not exceed 300 mm in length and are to discharge into a
tundish through an air gap of between 75 mm and 150 mm.
If a drain line discharges into a tundish, the drain line from the tundish must be
not less than DN20. The drain line from a tundish must meet the same
requirements as for a drain line from a relief valve.
Warning: As the function of the temperature pressure relief valve on this
water heater is to discharge high temperature water under certain conditions, it
is strongly recommended the pipe work downstream of the relief valve be
capable of carrying water exceeding 93°C. Failure to observe this precaution
may result in damage to pipe work and property.