Rheem Stellar 8A0 330 Owner's Manual And Installation Instructions
Rheem Stellar 8A0 330 Owner's Manual And Installation Instructions

Rheem Stellar 8A0 330 Owner's Manual And Installation Instructions

Gas domestic outdoor water heater stainless steel model

Advertisement

Owner's Guide
and

Installation Instructions

Gas Domestic Outdoor Water Heater
8A0 330 stainless steel model
This water heater must be installed and serviced by a qualified person.
Please leave this guide with the householder.

Advertisement

Table of Contents
loading

Summary of Contents for Rheem Stellar 8A0 330

  • Page 1: Installation Instructions

    Owner’s Guide Installation Instructions Gas Domestic Outdoor Water Heater 8A0 330 stainless steel model This water heater must be installed and serviced by a qualified person. Please leave this guide with the householder.
  • Page 2 PATENTS This water heater may be protected by one or more patents or registered designs in the name of Rheem Australia Pty Ltd or Aquamax Australia Pty Limited. TRADEMARKS ® Registered trademark of Rheem Australia Pty Ltd.
  • Page 3: Table Of Contents

    CONTENTS HOUSEHOLDER – We recommend you read pages 4 to 22. The other pages are intended for the installer but may be of interest. About Your Water Heater ............4 Regular Care ................12 Water Supplies ................15 Save A Service Call ..............19 Installation ..................
  • Page 4: About Your Water Heater

    The model is a high efficiency, quick recovery 8A0 series Rheem Stellar™ 330 stainless steel water heater. Water is stored in a stainless steel cylinder and heated by a gas burner located under the cylinder.
  • Page 5 Note: Where a temperature limiting device is fitted to the hot water pipe work after a Rheem Stellar 330 stainless steel model, the dial of the water heater‟s adjustable water mixing valve must be set on position „5‟. Refer to “Adjustable...
  • Page 6 Owner‟s Guide and Installation Instructions. The Rheem warranty may not cover faults if relief valves or other safety devices are tampered with or if the installation is not in accordance with these instructions.
  • Page 7 5. Adjustable Water Mixing Valve The Rheem Stellar 330 stainless steel model has a user adjustable water mixing valve. The adjustment dial is located on the left hand side of the water heater, between the cold water inlet and hot water outlet connections.
  • Page 8 Note: When a temperature limiting device is fitted to the hot water pipe work downstream of a Rheem Stellar 330 stainless steel model or if the water heater is installed as part of a circulated flow and return system, the dial of the water heater‟s adjustable water mixing valve must be set on position „5‟.
  • Page 9 ABOUT YOUR WATER HEATER Notes If the adjustable water mixing valve is set on the lowest setting (position „1‟) and the delivered water temperature is still too hot, then reduce the thermostat setting on the gas control and wait twenty four (24) hours before “Gas Control Temperature Dial”...
  • Page 10 ABOUT YOUR WATER HEATER TO TURN OFF THE WATER HEATER If it is necessary to turn off the water heater: “Close Down Procedure” Shut down the gas control (refer to on page 43). Close the gas isolation valve at the inlet to the gas control. Close the cold water isolation valve at the inlet to the water heater.
  • Page 11 ABOUT YOUR WATER HEATER DOES THE WATER CHEMISTRY AFFECT THE WATER HEATER? The water heater is suitable for most public water supplies, however some water chemistries may have detrimental effects on the water heater, its “Water Supplies” components and fittings. Refer to on page 15.
  • Page 12: Regular Care

    Phone Rheem Service or their nearest Accredited Service Agent. Note: The annual service and routine replacement of any components, if required, are not included in the Rheem warranty. A charge will be made for this work. Only genuine replacement parts should be used on this water heater.
  • Page 13 Note: The five (5) year service and routine replacement of any components, such as the relief valve(s), are not included in the Rheem warranty. A charge will be made for this work. Only genuine replacement parts should be used on this water heater.
  • Page 14 If water does not flow freely from the drain line when the lever is lifted, then the water heater must be checked. Phone Rheem Service or their nearest Accredited Service Agent to arrange for an inspection. The temperature pressure relief valve should be replaced at intervals not exceeding five (5) years, or more frequently in areas where there is a high “Water Supplies”...
  • Page 15: Water Supplies

    A list of postcodes is available on the Rheem website (www.rheem.com.au) indicating known areas where the stainless steel cylinder is not covered by the Rheem warranty due to the water chemistry of the area. The list is not necessarily exhaustive and there may be areas outside of these postcodes where the stainless steel cylinder is not covered by the Rheem warranty due to the water chemistry of the area.
  • Page 16 Where the pH is less than 6.0 or greater than 9.5, the Rheem warranty does not apply to a stainless steel cylinder. Water with a pH less than 6.0 may be treated to raise the pH.
  • Page 17 Where the saturation index exceeds +0.40, the water is very scaling. An expansion control valve must be fitted on the cold water line after the non- return valve to protect and for the Rheem warranty to apply to the temperature pressure relief valve and water heater cylinder.
  • Page 18 WATER SUPPLIES TOTAL DISSOLVED SOLIDS The stainless steel cylinder of the water heater is only covered by the Rheem warranty when the total dissolved solids (TDS) content in the water is less than 600 mg / L. Note: Some water analysis reports may state the conductivity of the water rather than the level of total dissolved solids.
  • Page 19: Save A Service Call

    Warning: Hotter water increases the risk of scald injury. Water heater size Do you have the correct size water heater for your requirements? The sizing guide in the Rheem sales literature and on the Rheem website (www.rheem.com.au) suggests average sizes that may be needed.
  • Page 20 The gas control must be turned off using the knob on top of the gas control “Close Down Procedure” thermostat (refer to on page 43). Phone Rheem Service or nearest Accredited Service Agent to arrange for inspection.
  • Page 21 SAVE A SERVICE CALL EXPANSION CONTROL VALVE RUNNING If an expansion control valve is fitted in the cold water line to the water heater (refer to page 32) it may discharge a small quantity of water instead of the temperature pressure relief valve on the water heater. The benefit is that energy is conserved as the discharged water is cooler.
  • Page 22 Has your water heating tariff rate been increased by your gas retailer since your previous bill? Check your previous bill and compare gas rates and charges. IF YOU HAVE CHECKED ALL THE FOREGOING AND STILL BELIEVE YOU NEED ASSISTANCE, PHONE RHEEM SERVICE OR THEIR NEAREST ACCREDITED SERVICE AGENT.
  • Page 23: Installation

    INSTALLATION THIS WATER HEATER IS FOR OUTDOOR INSTALLATION ONLY. THIS WATER HEATER IS NOT SUITABLE FOR POOL HEATING. Check the water heater is suitable for the gas type available (refer to the rating label affixed behind the access cover on the water heater). INSTALLATION STANDARDS The water heater must be installed: by a qualified person, and...
  • Page 24 500 mm above, below and either side the flue terminal. Failure to observe this precaution can cause problems in high wind areas. Alternatively, the water heater may be installed partially recessed into an external wall. A flashing kit for a recessed installation is available from Rheem. “Flashing Kit” Refer to on page 27.
  • Page 25 INSTALLATION The water heater must not be installed in an area with a corrosive atmosphere where chemicals are stored or where aerosol propellants are released. Remember the air may be safe to breathe, but when it goes through a flame, chemical changes take place which may attack the water heater.
  • Page 26 Note: If the cylinder is damaged as a result of attaching pipe clips or saddles to the jacket, any resultant faults will not be covered by the Rheem warranty.
  • Page 27 A Flashing Kit (PN AQ1064105) for a recessed installation is available from Rheem. It is sold separately to the water heater. The Flashing Kit must not be installed within a 100 mm wide vertical strip either side of the cold water inlet, hot water outlet and temperature pressure relief valve.
  • Page 28 Note: When a temperature limiting device is fitted to the hot water pipe work downstream of a Rheem Stellar 330 stainless steel model, the dial of the water heater‟s adjustable water mixing valve must be set on position „5‟. Refer to “Adjustable Water Mixing Valve”...
  • Page 29 INSTALLATION CIRCULATED HOT WATER FLOW AND RETURN SYSTEM If a Rheem water heater is to be installed as part of a circulated hot water flow and return system, a storage water heater able to provide a hot water outlet temperature of at least 60°C must be used. Note: The thermostat must always be set to at least 60°C.
  • Page 30 INSTALLATION TYPICAL INSTALLATION – OUTDOOR LOCATION WALL BRACKET TEMPERATURE PRESSURE RELIEF VALVE FLUE TERMINAL Minimum distance to TEMPERATURE windows, doors and PRESSURE RELIEF walls must be in VALVE DRAIN LINE accordance with Drain line must regulatory authority terminate away from the requirements.
  • Page 31 INSTALLATION DIMENSIONS AND TECHNICAL DATA VALVE INLET VALVE TOP OF FLUE TERMINAL 1625 1405 OUTLET INLET COLD INLET ACCESS COVER DIMENSION DRAWING 8A0 330 Gas Details – Natural Gas Model STAINLESS STEEL GAS WATER HEATER Storage capacity Hourly Gas Consumption (MJ) litres Hourly recovery...
  • Page 32: Connections - Plumbing

    CONNECTIONS – PLUMBING All plumbing work must be carried out by a qualified person and in compliance with the Standard AS/NZS 3500.4 and all local codes and regulatory authority requirements. All gas work must be carried out by a qualified person and in compliance with the Standard AS 5601 or AS/NZS 5601.1, as applicable under local regulations, and all local codes and regulatory authority requirements.
  • Page 33 CONNECTIONS – PLUMBING TEMPERATURE PRESSURE RELIEF VALVE The temperature pressure relief valve is shipped behind the front cover. The temperature pressure relief valve must be fitted before the water heater is operated. Before fitting the relief valve, make sure the probe has not been bent. Seal the thread with Teflon tape - never hemp.
  • Page 34 CONNECTIONS – PLUMBING RELIEF VALVE DRAIN DN15 copper drain lines must be fitted to the temperature pressure relief valve and expansion control valve (if one is installed) to carry the discharge clear of the water heater. Connect the drain lines to the valves using disconnection unions.
  • Page 35 Warning: Always isolate the water heater before pressure testing the gas supply system. Disconnect the water heater after the isolating cock to prevent the risk of serious damage to the gas control. The Rheem warranty does not cover damage of any nature resulting from failure to observe this precaution.
  • Page 36: Commissioning

    COMMISSIONING TO FILL AND TURN ON THE WATER HEATER The gas pilot or burner must not be lit until the water heater is filled with water. Open all of the hot water taps in the house (don‟t forget the shower). Open the cold water isolation valve fully to the water heater.
  • Page 37 COMMISSIONING GAS INLET PRESSURE IMPORTANT – CHECK the gas supply pressure at the inlet to the water heater with the water heater and all other gas burning appliances in the premises operating (burners alight). The minimum gas supply pressure for Natural Gas is 1.13 kPa. If this minimum cannot be achieved, it may indicate the meter or the gas line to the water heater is undersized.
  • Page 38 COMMISSIONING BURNER GAS PRESSURE TESTING AND ADJUSTMENT The burner gas pressure must be checked and adjusted (if required) as part of the commissioning procedure. Refer to Gas Details in the table on page 31 or check the rating label of the water heater for the burner test point pressure with the burner operating.
  • Page 39 Note: If the test point pressure cannot be adjusted to within 5% of the specified value for a natural gas model, complete this procedure and phone Rheem Service or their nearest Accredited Service Agent to arrange for an inspection. “Close Down Procedure”...
  • Page 40: Lighting The Water Heater

    If the gas smell is throughout the area, turn the gas control knob clockwise to the “” (off) position and then turn off the isolation valve on the gas line to the water heater. Leave the area and call Rheem Service or a qualified service technician.
  • Page 41 LIGHTING THE WATER HEATER LIGHTING INSTRUCTIONS Using the gas control light the water heater as follows: “Safety Information” Stop, read the on page 40. Remove the access cover. Depress the gas knob slightly and turn fully clockwise so the white dot “”...
  • Page 42 Adjustment” on pages 37 and 38. If the test point pressure cannot be adjusted to within 5% of the specified value, refer to Rheem Service or their nearest Accredited Service Agent. If unable to get the water heater working properly, contact Rheem Service or their nearest Accredited Service Agent.
  • Page 43 LIGHTING THE WATER HEATER CLOSE DOWN PROCEDURE Remove the access cover. Depress the gas knob slightly and turn it clockwise so the red star “ ” (pilot position) faces the front, aligning with gas knob position indicator. This setting will leave the pilot flame alight, however the main burner will not be able to light.
  • Page 44: Draining The Water Heater

    DRAINING THE WATER HEATER Warning: Exercise care, as water discharged from the water heater may be of a very high temperature. To drain the water heater: “To Turn Off The Water Heater” Turn off the water heater (refer to page 39). Close all hot water taps.
  • Page 45 This page is intentionally blank.
  • Page 46: Warranty

    2.1 The decision of whether to repair or replace a faulty component is at Rheem’s sole discretion. 2.2 If you require a call out and we find that the fault is not covered by the Rheem warranty, you are responsible for our standard call out charge. If you wish to have the relevant component repaired or replaced by Rheem, that service will be at your cost.
  • Page 47 3. WHAT IS COVERED BY THE RHEEM WARRANTY FOR THE WATER HEATERS DETAILED IN THIS DOCUMENT 3.1 Rheem will repair or replace a faulty component of your water heater if it fails to operate in accordance with its specifications as follows:...
  • Page 48 6.2 The Rheem warranty (set out above) is in addition to any rights and remedies that you may have under the Australian Consumer Law.

Table of Contents