64
Hardware Maintenance Manual A40 Type 6840 A40P Type 6841 A40i Type 2271: IBM NetVista Computer
POST Error Code
1102
Card selected feedback error
1103
Port fails register check
1106
Serial option cannot be turned off
1107
1110
Register test failed
1116
Interrupt error
1117
Failed baud rate test
1162
Serial port configuration error
11XX
Not listed above
1201
1202, 1206, 1208, 1209, 12XX
1207
13XX
1402
Printer not ready
1403
No paper error, or interrupt failure
1404
System board timeout failure
1405
Parallel adapter error
1406
Presence test error
14XX
Not listed above. Check printer before
replacing system board
15XX
1692
Boot sequence error
FRU/Action
1. Run diagnostics
1. Run diagnostics
2. System Board
1. Run diagnostics
2. System Board
1. Serial Device Cable
2. System Board
1. Run diagnostics
2. System Board
1. Run diagnostics
1. Run diagnostics
1. Run Configuration
2. Serial Adapter
(if installed)
3. System Board
1. System Board
1. System Board
2. Any Serial Device
1. Dual Async Adapter/A
2. System Board
3. Any Serial Device
1. Communications Cable
2. Dual Async Adapter/A
1. Game Adapter
Information only
Information only
1. Run diagnostics
1. Run diagnostics
1. Run diagnostics
1. Printer
2. System Board
1. SDLC Adapter
1. Run FDISK to ensure at least one active
partition is set active