Download Print this page
Carrier HRVCCLHA Product Data

Carrier HRVCCLHA Product Data

Heat recovery ventilators
Hide thumbs Also See for HRVCCLHA:

Advertisement

HRVCCLHA, HRVCCSVA, HRVCCSHA
Heat Recovery Ventilators
HRVCCLHA
HRVCCSVA
HRVCCSHA
Product Data
The Heat Recovery Ventilation (HRV) system offered by Carrier
is the finest on the market today. The HRV provides efficient and
cost effective heat recovery during the heating season when
needed most.
As temperatures drop below 23_F (- -5_C), indoor air is
recirculated periodically through the heat exchanger core to
prevent
supplementary electric defrost waste energy. Unlike rotary wheel
heat exchangers which mix air streams, these cross- -flow or
counterflow heat exchangers ensure that there is no mixing of the
stale air stream with the fresh outdoor air stream.
A filter installed on the incoming outdoor air stream removes
large airborne particles from the intake air stream before they
enter the heat exchanger and reduces the maintenance required.
The units' acoustically engineered design makes the Carrier HRV
the quietest on the market and ensures that comfort is felt, not
heard.
Unlatching two (2) suitcase style latches allows easy removal of
the filters and core for cleaning.
NOTE: The HRV should not be installed in an attic or
unconditioned space unless provisions are made for drainline
freezing and condensation.
S Energy saving defrost cycle
S Cross- -flow, counterflow heat exchangers
S One filter on incoming air; one filter on outgoing air to
protect core
S Acoustical design
S No- -tools maintenance
S Polypropylene heat exchanger core
1
frost
from
forming.
Competitors'
STANDARD FEATURES
methods
of

Advertisement

loading

Summary of Contents for Carrier HRVCCLHA

  • Page 1 HRVCCLHA, HRVCCSVA, HRVCCSHA Heat Recovery Ventilators Product Data The Heat Recovery Ventilation (HRV) system offered by Carrier is the finest on the market today. The HRV provides efficient and cost effective heat recovery during the heating season when needed most.
  • Page 2: Model Number Nomenclature

    Model number nomenclature Brand: Electrical Supply: Maximum Capacity: Carrier 1--- 115 Volts 100 CFM 150 CFM Equipment Type: 250 CFM Descriptor (A Series): Heat Recovery Ventilator LHA --- Large Horizontal SVA --- Small Vertical SHA --- Small Horizontal Climate Map for Energy and Heat Recovery Ventilators...
  • Page 3 Controls and accessories part number nomenclature CONTROL DESCRIPTION CAU--- Carrier Automatic Control CBS--- Carrier Basic Control CST--- Carrier Standard Control ACCESSORY DESCRIPTION 6FM--- 6 in. Flowmeters (2) 7FM--- 7 in. Flowmeters (2) 01--- Single Pack 8FM--- 8 in. Flowmeters (2)
  • Page 4 BELOW ---18_F (---5_C TO ---15_C) (---15.6_C TO ---27.3_C) (---27.8_C) Model Model DEFROST* EXCHANGE{ DEFROST* EXCHANGE{ DEFROST* EXCHANGE{ HRVCCLHA 6 Minutes 60 Minutes 6 Minutes 32 Minutes 6 Minutes 20 Minutes HRVCCSHA 6 Minutes 60 Minutes 6 Minutes 32 Minutes 6 Minutes...
  • Page 5 A05228 Model HRVCCLHA1150 17-1/4 438.2 10-1/2 266.7 4-1/2 114.3 279.4 HRVCCLHA1250 17-1/4 438.2 10-1/2 266.7 4-1/2 114.3 279.4 Model HRVCCLHA1150 7-3/4 196.9 4-3/8 111.1 7-3/4 196.9 HRVCCLHA1250 7-3/4 196.9 5-13/16 147.6 7-3/4 196.9 Fig. 1 - - HRVCCLHA Unit Dimensions...
  • Page 6: Physical Data

    A05426 Fig. 2 - - HRVCCSHA Unit Dimensions A05425 Fig. 3 - - HRVCCSVA Unit Dimensions Physical data Model HRVCCLHA1150 HRVCCLHA1250 HRVCCSVA1100 HRVCCSHA1100 Port Locations Side Side Side Core Type Core Type Polypropylene Polypropylene Polypropylene Polypropylene Polypropylene Polypropylene Polypropylene Polypropylene Cross Flow Cross Flow Cross Flow...
  • Page 7 Physical data (continued) Model HRVCCLHA1150 HRVCCLHA1250 HRVCCSVA1100 HRVCCSHA1100 Capacity—CFM @ 130--- 168 191--- 210 99--- 107 99--- 107 0.5-0.3ESP (in. wc) Efficiency (Sensible)—Percent Efficiency (Sensible) Percent 32_F (0_ C) -- 13_F (-- 25_ C) Efficiency (Latent)—Percent @ all temperatures Heat Core Exchange Area— cu ft (cu m) 120 (3.4) 166 (4.7)
  • Page 8 COOLING LOAD BTU The cooling load chart shows the loads in BTUh also. To use the Cooling Load (BTUh) @ Inside Design cooling load chart, first find the design enthalpy from a Outside Outside Temp 75°F and 50% Relative Humidity psychrometric chart using the design dry bulb and wet bulb Enthalpy temperatures.
  • Page 10 HRV installed with forced air system A99297 HRV installed with independent air distribution A99298 Copyright 2005 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 12/05 Catalog No: HRV ---4PD Replaces: New Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.