Product Data
The Heat Recovery Ventilation (HRV) system offered by Carrier is
the finest on the market today. These HRV units provide efficient
and cost effective heat recovery during the heating season when
needed most.
As temperatures drop below 23_F (- -5_C), indoor air is recirculated
periodically through the heat exchanger core to prevent frost from
forming. Competitors' methods of supplementary electric defrost
waste energy. Unlike rotary wheel heat exchangers which mix air
streams, these cross- -flow heat exchangers ensure that there is no
mixing of the stale air stream with the fresh outdoor air stream.
A filter installed on the incoming outdoor air stream removes large
airborne particles from the intake air stream before they enter the
heat exchanger and reduces the maintenance required. The units'
acoustically engineered design makes the Carrier HRV the quietest
A11189
on the market and ensures that comfort is felt, not heard.
Unlatching two (2) suitcase style latches allows easy removal of the
filters and core for cleaning on LVU model.
NOTE:
unconditioned space unless provisions are made for drain line
freezing and condensation.
S Energy saving defrost cycle
S Cross- -flow heat exchangers
S One filter on incoming air; one filter on outgoing air to protect
core
S Acoustical design
S No- -tools maintenance
S Polypropylene heat exchanger core
A11244
S SVU model meets Energy Star Canada requirements
The HRV should not be installed in an attic or
STANDARD FEATURES

Advertisement

Table of Contents
loading

Summary of Contents for Carrier HRVXXSVU

  • Page 1 HRVXXSVU HRVCCLVU Heat Recovery Ventilator Product Data The Heat Recovery Ventilation (HRV) system offered by Carrier is the finest on the market today. These HRV units provide efficient and cost effective heat recovery during the heating season when needed most.
  • Page 2: Model Number Nomenclature

    Maximum Capacity HRV - - Heat Recovery Ventilator 157 - - 157 CFM 330 - - 330 CFM Brand CC - - Carrier XX - - Carrier Electrical Supply 1 - - 115 Volts Description LVU - - Large Vertical Unit...
  • Page 3 Used with HRVCCLVU 1330 Unit 14--- 3/8 x 15--- 1/2 (1) KVAFL0101810 Internal Filter Used with HRVCCLVU 1330 Unit 8--- 1/8 x 10--- 3/4 (1) 18204 (RCD) Internal Filter Used with HRVXXSVU 1157 Unit 9--- 1/4 x 14--- 1/4 (2)
  • Page 4 DIMENSIONS 9/ 16 ″ NOTES: [446.9] 1. FRESH AIR FROM OUTSIDE TO HRV 13/ 16 ″ 2. FRESH AIR FROM HRV TO HOUSE ″ DIA 1/ 8 [147.6] Ú ″ 3. STALE AIR FROM HOUSE TO HRV [206.4] [120.6] 2 PLCS 4.
  • Page 5: Physical Data

    PHYSICAL DATA MODEL HRVXXSVU1157 HRVCCLVU1330 Port Locations Polypropylene Cross Flow Polypropylene Cross Flow Core Type Weight — lb (kg) 52 (23.6) 120 (54.5) Shipping Weight — lb (kg) 56 (25.4) 143 (64.9) Dimensions in. (mm) Height 24--- 9/16 (624) 43 (1092) Width 23--- 9/16 (599) 24 (608)
  • Page 6: Control Features

    23°F TO 55°F (–5°C TO –15°C) 4°F TO –17°F (–15.6°C TO –27.3°C) BELOW –18°F (–27.8°C) MODEL DEFROST* EXCHANGE[ DEFROST* EXCHANGE[ DEFROST* EXCHANGE[ HRVXXSVU 6 Minutes 60 Minutes 6 Minutes 32 Minutes 6 Minutes 20 Minutes HRVCCLVU 6 Minutes 60 Minutes...
  • Page 7 ADDITIONAL HEATING AND COOLING LOAD CHARTS Although the ventilators process the outside air before it enters the home, additional heating and cooling loads need to be considered. HEATING LOAD BTU HEAT LOAD (BTUH) @ INSIDE OUTSIDE DESIGN TEMP 72°F TEMP °F SVU1157 LVU1330 –25...
  • Page 9 HRV INSTALLED WITH FORCED AIR SYSTEM A99297 HRV INSTALLED WITH INDEPENDENT AIR DISTRIBUTION A99298...
  • Page 10 Catalog No: HRV ---04PD Copyright 2011 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 05/11 Replaces: HRV--- 3PD Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.