HRVCCLHU
Copyright 2005 Carrier Corporation
Product
Data
HRVCCLVU
Heat Recovery Ventilators
HRVCCSVC
HRVCCLHU
HRVCCSVC
HRVCCLVU
The Heat Recovery Ventilation
(HRV) system offered by Carrier is
the finest unit on the market today.
The HRVC provides efficient and cost-
effective heat recovery during the
heating season when needed most.
As temperatures drop below 23°F
(–5°C), indoor air is recirculated
periodically through the heat
exchanger core to prevent frost from
forming. Competitors' methods of
supplementary electric defrost waste
energy. Unlike rotary wheel heat
exchangers which mix air streams,
these cross flow or counterflow heat
exchangers ensure that there is no
mixing of the stale air stream with
the fresh outdoor air stream.
A filter installed on the incoming
outdoor air stream removes large
airborne particles from the intake air
stream before they enter the heat
exchanger and reduces the
maintenance required.
The units' acoustically engineered
design makes them the quietest on
the market and ensures that comfort
is felt, not heard.
Unlatching 2 suitcase style latches
allows easy removal of the filters and
core for cleaning.
Note: The HRV should not be
installed in an attic or unconditioned
space unless provisions are made for
drainline freezing and condensation.
FEATURES
• Energy saving defrost cycle
• Cross flow, counterflow heat
exchangers
• One filter on incoming air;
one filter on outgoing air to
protect core
• Acoustical design
• No-tools maintenance
• Polypropylene heat exchanger core
Form HRV-2PD

Advertisement

loading

Summary of Contents for Carrier HRVCCLHU

  • Page 1 HRVCCSVC Data HRVCCLVU Heat Recovery Ventilators The Heat Recovery Ventilation (HRV) system offered by Carrier is the finest unit on the market today. The HRVC provides efficient and cost- effective heat recovery during the heating season when needed most. As temperatures drop below 23°F (–5°C), indoor air is recirculated...
  • Page 2: Model Number Nomenclature

    330 CFM Electrical Supply: 1 — 115 volts Descriptor: LHU — Large Horizontal Unit SVU — Small Vertical Unit LVU — Large Vertical Unit Brand: Carrier Equipment Type: Heat Recovery Ventilator TESTED/CERTIFIED ® HOME VENTILATING INSTITUTE DIVISION OF AMCA Climate Map for Energy and Heat Recovery Ventilators...
  • Page 3 At start up, when 8 in. duct work is connected to HRV KVAFK0101150 Internal Filter Used with HRVCCLHU 1150 Unit 11 3/4 x 12 7/8 x 3/4 (2) KVAFK0201200 Internal Filter Used with HRVCCLHU 1250 Unit 11 3/4 x 16 3/4 x 3/4 (2)
  • Page 4 23°F TO 55°F (–5°C TO –15°C) 4°F TO –17°F (–15.6°C TO –27.3°C) BELOW –18°F (–27.8°C) MODEL DEFROST* EXCHANGE† DEFROST* EXCHANGE† DEFROST* EXCHANGE† HRVCCLHU 6 Minutes 60 Minutes 6 Minutes 32 Minutes 6 Minutes 20 Minutes HRVCCSVU 6 Minutes 60 Minutes...
  • Page 8: Physical Data

    Physical data MODEL DESCRIPTION CONVENTIONAL COMPACT HIGH EFFICIENCY Model No. HRVCCVHU1150 HRVCCVHU1260 HRVCCSVC1150 HRVCCSVC1200 HRUCCLVU1150 HRUCCLVU1200 HRUCCLVU1330 Port Locations Sides Sides Core Type Polypropylene Polypropylene Polypropylene Polypropylene Polypropylene Polypropylene Polypropylene Cross Flow Cross Flow Cross Flow Cross Flow Cross Flow Counterflow Counterflow Weight —...
  • Page 9 Methods to size HRV’s METHOD 1 1. Calculate cu ft of occupied space. 2. Multiply by recommended air changes per hr (AC/h). 3. Divide by 60 minutes per hr to convert to CFM. EXAMPLE: 2000 sq ft with 8 ft ceiling 0.35 air changes per hr (AC/h) (2000 sq ft x 8 ft ceiling x 0.35 AC/h) / 60 min/h = 93.3 CFM METHOD 2...
  • Page 10 Cooling load BTU Outside Cooling Load (Btuh) @ Inside Design Temp 75°F and 50% Relative Humidity Enthalpy Btu/lb HRVCCLHU1150 HRVCCLHU1250 HRVCCSVC1150 HRVCCSVC1200 HRVCCLVU1150 HRVCCLVU1200 HRVCCLVU1330 1,071 1,390 1,090 1,741 1,300 1,650 1,290 1,650 2,310 1,509 2,411 1,820 2,310 1,800 2,310 3,240 1,928 3,080...
  • Page 12 HRV installed with forced air system A99297 HRV installed with independent air distribution A99298 • Copyright 2005 Carrier Corporation Indianapolis, IN 46231 04-05 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book Page 12 Printed in U.S.A.

This manual is also suitable for: