3.
Select Settings > Master Communication Settings from the Main menu to open the Master
Communication Settings dialog (FIG. 76).
FIG. 76
Assigning Communication Settings and TCP/IP Settings
4.
Click the Communications Settings button to open the Communications Settings dialog.
5.
Click on the NetLinx Master radio button (from the Platform Selection section) to indicate you are
working with a NetLinx Master (such as the NXC-ME260/64 or NI-Series of Integrated Controllers).
6.
Click on the TCP/IP radio button (from the Transport Connection Option section) to indicate you are
connecting to the Master through an IP Address.
7.
Click the Edit Settings button (on the Communications Settings dialog) to open the TCP/IP Settings
dialog (FIG. 76). This dialog contains a series of previously entered IP Address/URLs and their
associated names, all of which are stored within Studio and are user-editable.
8.
Click the New button to open the New TCP/IP Settings dialog where you can enter both a previously
obtained DHCP or Static IP Address and an associated description for the connection into their respective
fields.
9.
Place a checkmark within the Automatically Ping the Master Controller to ensure availability radio box
to make sure the Master is initially responding online before establishing full communication.
10.
Click OK to close the current New TCP/IP Settings dialog and return to the previous TCP/IP Settings
dialog where you must locate your new entry within the List of Addresses section.
11.
Click the Select button to make that the currently used IP Address communication parameter.
12.
Click OK to return to the Communications Settings dialog and place a checkmark within the
Authentication Required radio box if your Master has been previously secured with a username/password.
13.
Click on the Authentication Required radio box (if the Master is secured) and then press the User Name
and Password button to open the Master Controller User Name and Password dialog.
14.
Within this dialog, you must enter a previously configured username and password (with sufficient rights)
before being able to successfully connect to the Master.
15.
Click OK to save your newly entered information and return to the previous Communication Settings
dialog where you must click OK again to begin the communication process to your Master.
NXD/T-1200V 12" Modero® Video Wall/Flush Mount Touch Panel
Upgrading Modero Firmware
77