Firmware Pages and Descriptions
System Settings Page Elements (Cont.)
Primary DNS
Secondary DNS
Domain
Ethernet Mode
MAC Address
Master Connection:
Type
Mode
System Number
Master IP/URL
Master Port Number
Username/Password
Refer to the Step 2: Choosing a Master Connection Mode Setting section on page 63 for more detailed
information on using the System Settings page.
108
Sets the address of the primary DNS server used for host name lookups.
• DNS (Domain Name System) is software that lets users locate computers on
a local network or the Internet (TCP/IP network) by host and domain. The
DNS server maintains a database of host names for its' domain and their
corresponding IP Addresses.
Sets a secondary DNS value to the panel.
Sets the unique name on the Internet to the panel for DNS look-up.
• The panel belongs to the DNS domain.
Sets the speed of the Ethernet connection to the panel.
• Choices are: Auto, 10 Half Duplex, 10 Full Duplex, 100 Half Duplex, or
100 Full Duplex.
Displays a read-only field that is factory set by AMX for the built-in Ethernet
interface.
Sets the NetLinx Master communication values:
Sets the NetLinx Master to communicate with the panel via either USB or
Ethernet. This is based on the cable connection from the rear.
ICSNet is not a supported option on this panel.
• Ethernet is a CAT-5 cable (10/100Base T terminated in an RJ-45 connector)
used to network computers together and is used in most LAN (local area
networks). This description is also used to refer to both wired and wireless
communication.
• USB option cannot be used on Modero panels which are not equipped with a
rear USB port.
Cycles between the different connection modes (URL, Listen, and Auto)
(ETHERNET Only - disabled when USB is selected)
• URL - In this mode, enter the IP/URL, Master Port Number, and
username/password (if used) on the Master.
- The System Number field is read-only because the panel obtains this
information from the communicating Master.
• Listen - In this mode, add the Modero panel address into the URL List in
NetLinx Studio and set the connection mode to Listen. This mode allows the
Modero touch panel to "listen" for the Master's communication signals.
- The System Number and Master IP/URL fields are red-only.
• Auto - In this mode, enter the System Number and a username/password
(if applicable). This mode is used when both the panel and the NetLinx
Master are on the same Subnet and the Master has its UDP feature enabled.
- Master IP/URL field is read-only.
Allows you to enter a system number. Default value is 0 (zero).
(ETHERNET Only - disabled when USB is selected)
Sets the Master IP or URL of the NetLinx Master.
(ETHERNET Only - disabled when USB is selected)
Allows you to enter the port number used with the NetLinx Master.
• Default value is 1319. (ETHERNET Only - disabled when USB is selected)
If the target Master has been previously secured, enter the alpha-numeric string
(into each field) assigned to a pre-configured user profile on the Master.
This profile should have the pre-defined level of access/configuration rights.
NXD/T-1200V 12" Modero® Video Wall/Flush Mount Touch Panel