The MDR-8000 application software offers user password security management using two
different levels of passwords. User security deals with access level assigned to specific
users. The level of user security affects the type and number of commands an individual
user may execute. This prevents an unqualified user's access to high-level commands.
Level 1 password allows the user to view screens. Level 2 password allows access to all
functions and is the highest level. A Level 2 password is required to make changes and
save the changes.
TEST PROCEDURES
4.4
The radio has been properly aligned and tested at the factory before shipment eliminating
the need for testing after initial turn-up. The only time testing and/or adjustment is
required is after a maintenance action such as removal and replacement procedure and/or
constant alarms requiring corrective maintenance action. The completed maintenance
action procedure(s) will reference any required test procedure(s).
PROVISIONING RADIO
4.5
Changes to provisioning do not have to be made in any particular
order.
Open radio provisioning screens. On main screen, double click on tower icon. Status and
alarm screen displays. Click on Provisioning. Check current provisioning and change as
required. See Figure 4 - 1 for recommended sequence.
4-2
Note