Mcs-11 Operation - Alcatel MDR-8000 User Manual

Microwave digital radios
Hide thumbs Also See for MDR-8000:
Table of Contents

Advertisement

1. OPEN USI CONTROLS SCREEN.
Controls -- MDR-8000 DS3
File
View Setup Options
F4
F5
Alarm Status
Analog Monitor
ELMC Address:
J7915
Description:
SILVERTON
IN-SERVICE
A Transmitter On Line
B Transmitter On Line
A Receiver On Line
B Receiver On Line
A I/O On Line
B I/O On Line
A ATPC HIGH Power Lock
B ATPC HIGH Power Lock
A ATPC LOW Power Lock
B ATPC LOW Power Lock
Thursday, November 30, 2000
Figure 2-4 I/O Manual Switch Using USI Control Screen

MCS-11 Operation

2.4.4
An Operational Support System (OSS) provides a means to remotely monitor and control
an MDR-8000 radio via an MCS-11 Monitor and Control System polling master. A Remote
Station Summary (RSS), a Remote Detail Scanner (RDS), a Remote Analog Scanner (RAS),
and a Remote Control Decoder (RCD) are available at the polling master for each radio
network element. The remote station OSS addresses are programmed during radio provi-
sioning using the USI laptop computer. (Refer to radio provisioning in the Initial Turn-Up
section.) Refer to the attached CD for MCS-11 details, including alarm/status mapping and
connector information.
F6
F7
Performance
Station Alarm
LOCAL CONTROLS
Communicating*
SYSTEM LOOP-BACK
A I/O LOOPBACK
B I/O LOOPBACK
USER CONTROLS
2. SELECT I/O INTERFACE MODULE TO PUT IN-SERVICE.
Control #1
3. SELECT YES ON CONFIRMATION MESSAGE
TO ENABLE FUNCTION.
Control #2
Control #3
4. VERIFY GREEN IN-SERVICE STATUS CIRCLE DISPLAYS.
Control #4
Control #5
Control #6
1:44:19 PM
USI Version R1.02
F8
F9
User Control
Provisioning
DS1 LINE LOOP-BACK RCV to XMT
Line 1 loopback
Line 2 loopback
Line 3 loopback
Controller Version R1.02
LMW-5077-sm
08/15/02
2-7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mdr-8000iMdr-8000sMdr-8000u