Heat Pump Cooling - Bryant Evolution Connex SYSTXBBECW01 Installation Instructions Manual

Controller
Hide thumbs Also See for Evolution Connex SYSTXBBECW01:
Table of Contents

Advertisement

Low Heat Run Time: Selectable from 0 to 120 minutes
S
Default = 5 minutes
d
High Heat Run Time: Selectable from 0 to 120 minutes
S
Default = 5 minutes
d
Speed (variable speed heat pump only): Selectable from lowest available to
S
100%
Default = lowest available as specified by variable speed heat pump
d
Defrost: Yes or No
S
Default = No
d
6.4.6.

Heat Pump Cooling

The heat pump cooling mode can be exercised with this menu option. With a
2- - stage heat pump, a Low Cool Run Time and a High Cool Run Time are
independently selectable to exercise.
For variable speed heat pumps, you can select the speed at which the heat pump
will exercise.
After the selections are made, touch START.
NOTE: Airflows during Checkout modes are fixed to the EFFICIENCY setting
and are independent of other airflow settings. To view airflows for normal air
conditioning cooling mode, exit the CHECKOUT screen and apply a heating
demand to the system.
Low Cool Run Time: Selectable from 0 to 120 minutes
S
Default = 5 minutes
d
High Cool Run Time: Selectable from 0 to 120 minutes
S
Default = 5 minutes
d
Speed (variable speed heat pump only): Selectable from lowest available to
S
44